May 21, 2010
j
Catawba County
Permit Plan Review
76 North Center Street
Hickory, NC 28601
I RE: Case #: CBPR -4 -10 -4937
t St Stephens Fire Department
4060 Springs Road
I Conover, North Carolina
Building Review (Steve Deitz 05/04/2010)•
i
1 -9. We will comply as stated.
10. "C" drawings included in this submission have been signed and dated by an NC design
professional.
11. "Not for Construction" has been removed from the "C" drawings.
12. Stove anticipated to be a GE Profile # ZDP364NDPSS (See attached)
13. Dishwasher is "undercounter" type and ADA compliant for low 34" counter.
14. Hood remote actuation device located on the floor plan, Al as well as sheet M2.
15. Chief Industries metal building manufacturer design parameter provided (See attached)
16 -18. (See letter by En -Tech Engineering)
19. Letter by Chief Industries metal building manufacturer regarding hood provided (See attached)
20 -21. (See letter by En -Tech Engineering)
Fire Review (William Bump 04/26/2010)
1. We would like to field locate the fire extinguishers with the Fire Marshal to ensure optimal
coverage.
2 -4. (See letter by En -Tech Engineering)
5. A "Knox Box" will be provided and located per the fire department.
6 -11. 1 (See letter by En -Tech Engineering)
d
Thank you for your help on this project and feel free to contact myself or Brian Griffith with any additional
questions or comments you may have.
I
Sincerely,
s
i'
Michael G. Huslage, AIA
Consulting Architect
(
i
i
f
E r f
ENGINEERING EnTech Engineering, PA PO Box 11527 Goldsboro, NC 27532 919.778.9064
a
PME COMMENT RESPONSES
ENTECH Project Manager: Rod Brown
ENTECH Project No.: 210002
i
Response Date: May 19, 2010
3
Agency: County of Catawba
Project Name: St Stephens Fire Station
Reference No.: BLDC4-10 -6440
f
9
i
Note: Included are written PME comment responses with sufficient information, detail and document
references such that reviewers can readily check and clear the comments.
I
t
Building Comments - Reviewer: Steve Deitz
16. Hose bibs are provided in each room with a floor drain via wall mounted hose faucet or hose faucet
included with mop sink.
17. Note No. 3 added to Sheet M1.
18. Specific hood capacity information will be provided by the hood supplier with required detailed shop
drawings. Hood exhaust is not to exceed 800 CFM. Makeup air is provided via gas furnaces. A transfer
duct has been added to the kitchen to pull air from the building when hood is in use.
19. Bobbitt Response.
20. Typographical error corrected in Energy Report on Sheet M4.
21. The entire building load is supplied through the transfer switch. This switch is "Service Entrance
Rated" which means it will be equipped with a main breaker. This breaker is the service disconnect for
the building.
Fire Comments - Reviewer: William Bump
1. Bobbitt Response
2. No response necessary.
s
a
3. Fire sprinkler contractor will submit final design for approval.
4. Fire alarm contractor will submit final design for approval.
5. Bobbitt Response
6. Duct detectors are indicated to be connected to fire alarm system — See Fire Alarm Drawings
7. Hood installer will furnish detailed shop drawings.
8. Hood ansul system & fire sprinkler system are indicated to activate fire alarm system — See Fire Alarm
Drawings.
9. Exit sign is shown above the door and the "72" fixture at the Patio are emergency fixtures.
10. The "H1" fixtures in the stairwell are emergency fixtures.
11. Note No. 3 on Sheet FP -3 changed to Catawba County as required.
End of Comment Response.
t
f
,.
a
3
a
a
s
i
i
i
i
a
a
a
ti
B BB/ _ TT
.
{
May 17, 2010
i
Catawba County
Plan Review
76 North Center Street
Hickory, NC 28601
Reference: Project Name: St. Stephens Fire Department
Project ID.: BLDC -4-40 -6440
We have reviewed your comments for the referenced project and offer the following responses to
6 issues effecting Site Design:
Building Review — CBPR -4 -10 -4937 Reviewer: Steve Deitz
i
1 6 review:5 /4/2010 Disapproved
10. All Sheets beginning with 'C', shall be sealed, signed and dated by a Design Professional Licensed in
the State of North Carolina
x
-All Sheets sealed and signed
11. Remove 'Not for Construction' from all sheets that begin with 'C'
-Note has been removed from all `C' sheets.
Erosion Control Review — ECPR -4 -10 -4938 Reviewer: Toni Norton
1 5 review:4 /28/2010 Approved with Notes
Revise note for Temporary ground cover to specify 21 days
- Construction Sequence is revised, see sheet C2.0 for details.
Environmental Health Review — EHPR- 1- 10 -34 -92 Reviewer: Toni Norton
1S review:1 /19/2010 Approved
Zoning — ZON -4 -10 -4939 Reviewer_ : Chris Timberlake
1 5 review:4 /27/2010 Disapproved
Utilities — Provide verification from service provided that domestic service is available.
- Please find enclosed email from City of Hickory verifying service.
Traffic/Transportation — Provide documentation of NCDOT approved driveway permit prior to issuance of
Zoning Authorization Permit.
- Driveway Permit is pending. We will provide copy when available.
Signs — Actual wall and Free standing signs will require separate review and permits, through Permits Center.
- Noted.
i
s i nJe9 '4(
NORTH CAROLINA - 600 GERMANTOWN ROAD - RALEIGH, N.C. 27607 - 919 - 851 -1980 - FAX 919 - 851 -1982
SOUTH CAROLINA - 500 LAWAND DR., SUITE 103 - COLUMBIA, S.C. 29210 - 803 - 731 -5550 - FAX 803 - 731 -5580
i
i
Landscaping — Continue /wrap landscape strip to extend beside parking spaces. Revise perimeter screening
plantings to species providing faster maturity and coverage.
- Parking landscaping has been extended and perimeter landscaping has been
revised; see sheet C -5.0 for details
Zoning — Recombination of existing properties must be completed prior to issuance of Zoning Authorization
Permit.
- Noted.
Please call if you have any questions.
Sincerely,
BOBBITT DESIGN BUILD, INC.
Blair P. Pittman, PE
i
i
3
I
S
i
i
i
k
S-
CHIEF INDUSTRIES, INC.
3942 Old West Highway 30
May 14, 2010 P.O. Box 2078
Grand Island, Nebraska 68802 -2078
Re: Chief Quote No. QUOTE #9650402 Phone 308/389 - 7200 -Fax 308/389 -7221
Description: 82'x 132'x 18'
Builders Name: Bobbitt Design Build
Building Owners Name: St. Stephens Fire Department
Jobsite City, State: Conover, NC
Gentlemen:
Please accept this letter as certification that the Chief components, produced for the above
described project to be furnished to Bobbitt Design Build, for St. Stephens Fire Department, Conover, NC,
will be designed for the following criteria as specified by Purchaser in the order documents:
2006 MBMA Occupancy Category Essential Facilities Seismic
Roof Live Load 20 psf Spectral Response Short Periods (S 28%
(Tributary Area Reduction Allowed) Spectral Response 1 s Period (S 10%
Collateral Load 7 psf Seismic Importance Factor 1.5
Ground Snow Load (P 15 psf Design Category p
Exposure Factor (C.) 1.0 Site Class p
Thermal Factor (G) 1.0 Seismic Resisting System
Importance Factor (1) 1.2 Longitudinal Direction
Flat Roof Snow Load (P 12.6 psf Lateral Steel System (R =3.0)
p eral Direction Steel System (13=3.0)
Building Enclosure Enclosed Seismic Response Coefficient (C 0.126
Wind Speed 90 mph (GCpi ± 0.18) Spectral Response Parameter Short Period (SoS) 0.294
Exposure Category B Spectral Response Parameter 1 s Period (S 0.160
Importance Factor (1) 1.15 Analysis Procedure ELF
Wind Pressure (q) 14.19 psf Base Shear
98,998 lbs.
Other Loads:
800 Ibs Kitchen Exhaust Hood
and applied in accordance with the North Carolina 2009 Building Code.
The design of Chief structural steel components is in accordance with the provisions of the
NASPEC 2001 AISI Standard and the 13th Edition of AISC.
These Chief components as supplied, when properly erected as furnished, on an adequate
foundation, will meet the loading requirements supplied to Chief by Purchaser in accordance with good
engineering practices.
This certification does not cover field modifications nor does it cover materials furnished by
someone other than Chief Industries, Inc.; nor the connection between Chief components and those
manufactured or supplied by someone other than Chief Industries, Inc.
Chief design and detailing facilities: Grand Island, NE, Lincoln, NE, and Janesville, WI. Chief
Fabrication facilities: GrandjMatv*M,� and Rensselaer, IN.
CA /� '�•
Sincere)
SEAL
- F.
Quenti . Yada, P.E� Np.101$1 a
Sr. roject Engineer
Chief Industries, Inc. - B�
QY /tl , � t� + +e � a L• rj
E
ZDP364NDPSS (Natural Gas)
ZDP364LDPSS (Liquid Propane)
' GE Monogram° 36" Dual -Fuel Professional Range with 4 Burners and Griddl e
{
Dimensions and Installation Information (in inches)
Professional ranges offer a number of choices in size and
cooktop configurations.
I
All Professional Ranges are factory set for natural or liquid 35 -7/8" Width
f Counterto p
propane gas. The correct model should be ordered for the -- to Cooking
installation situation.,���°' Surface
Note: Conversion kits are included with the range if the wrong
gas type was ordered. High Altitude kit, WB28K10553 for _
operation above 3,000 feet (for Natural and LP gas models), is
also available. The kits must be installed by a qualified service ,
technician at additional cost. 35 -1/4" T '
Installation Information to
Before installing, consult installation instructions packed with Heigh
H
product or online at Monogrom.com for current dimensional Height 3 -1/4"
data. to 4 -3/4"
A 36" or 42" wide professional vent hood with a minimum 600 = -= - - - - --
CFM is recommended for installation over this r ange. 28 -1/4 - - - -- i
Advance Planning Toekick/Ieg
Depth Height
Refer to dimensional drawings for
to r
- €
appropriate placement and
necessary clearances when I ! 12' Minimum
i to Adjacent Wall
d
planning the installation. Mn, 5.
• Working areas adjacent to the ,A WARNING: i
range should have 18" minimum Installations without a hood require
clearance between countertop 48' minimum to combustibles.
A custom hood installation with 18.
and cabinet bottom. exposed horizontal combustible 13 __ ~_
surfaces must have an Auto -On Maxim — - Min.
• Clearance between range and feature. Refer to hood installation -
z;
side wall or combustible material instructions for specific hood
clearances. _
must be at least 12" on each side The surface of the entire back wall °
• Installation must conform with above the range and below the -
hood must be covered with a non- _ t -M �
local codes. In the absence of local combustible material such as metal 'o _ t
codes, the range must comply ceramic tile, brick, marble or other — l
stone. j
with the National Fuel Gas Code,
ANSI Z223.1- 1990.
)
Min.
= ADDITIONAL CLEARANCES: [
Allow 12' minimum clearance to an adjacent wall
on each side.
Working areas adjacent to the rangetop should have l
For answers to your Monogram ®GE Profile'" or 18 minimum clearance between countertop and
GE® appliance questions, visit our website at the bottom of the wall cabinet.
ge.com or call GE Answer Center® service,
800.626.2000.
Listed by
Underwriters
Laboratories
Imagination at work
Specification Created 7/08 130554
'd
•t
ZDP364NDPSS (Natural Gas)
ZDP364LDPSS (Liquid Propane)
GE Monogram° 36" Dual -Fuel Professional Range with 4 Burners and Gri
Dimensions and Installation Information (in inches)
Electrical Requirements Optional Backsplash Accessories
Ranges must be supplied with 208/240V, 60Hz, and connected The range requires a 12" minimum clearance to a vertical !
to an individual, properly grounded branch circuit protected combustible surface at the rear. A backsplash is required I
by a circuit breaker or time -delay fuse. Install a 30 -amp circuit for installations with less than 12" clearance. The following
for 36" ranges. The receptacle must be a NEMA 14 -SOR device backsplash accessories are available, or a custom, non -
to accept the four -prong plug on the range. combustible backsplash can be used.
Universal Utility Locations Order one with a 36" -wide range backsplash
ZX12B36PSS -12" backsplash
ZXADJ636PSS- 30 " -36" adjustable- height backsplash with E'
warming shelf i
f
4 -5/8" I
I
i
13 -3/8" 11 -3/8"
6 -1/2" r mss
2"
2"
36"
Locate gas and Side View with a Backsplash
electric as shown
- , °� — - - -► 12" Min. to combustibles or 0' to I
Gas Supply ' if — i' a non - combustible material above
13A - ►! I� i the cooking surface
• The natural gas models are designed to — --
operate at 5" water column pressure.
For proper operation, the pressure of 3os - * - ►
the natural gas supplied to the regulator 3 -3/,6•
must be between 7" and 13" water
column. _4 - -�- - -- �av�•T° - -- -- -� - --
to
• The LP models are designed to operate ;= E* of ew"
�1_ 0" Clearance
of 10" water column pressure. For P ane l s""°'° - I to a back or
side wall below
proper operation, the pressure of the. LP a&ii+ _ the cooking
n_,rr T°
gas supplied to the regulator must be W, surface F
DO* for
between 11" and 13" water column.
— — -- aav, `
For answers to your Monogrom®GE Profile" or T °rmmaooa
GE® appliance questions, visit our website at ' - -- T°RodOfH xh - -
ge.com or call GE Answer Center® service, ' - — -- - '&'/ - - - - -.I
With avarr oar O
800.626.20001
Usted by
L Underwriters
Laboratories �
imagination at work
411M
Specification Created 7/08 130554
r
ZBD1870NSS
GE Monogram ®18" Dishwasher
Features and Benefits
• Integrated Design - Offers a. stainless steel door
and slim tubular handle
• Hidden, Integrated Electronic Controls - Allow
easy activation of wash cycles: heavy wash,
normal wash, light wash, china and rinse only
• Five -Level Wash System - Provides effective, yet
quiet cleaning power j
• ENERGY STAR® Qualification - As an ENERGY /
STAR® partner GE has determined that the
Monogram" 18" dishwasher meets the ENERGY
STAR guidelines for energy efficiency and water
conservation
• Pearlescent Gray, Nylon- Coated Racks with
Ball- Tipped Tines - Provide plenty of space and t
loading flexibility
• StemSafe'" Shelf - Allows for odd - shaped items
and delicate stemware
• Model ZBD1870NSS - Stainless steel
I
e
I
P
p g § � .
yy
E
For answers to your Monogram ® GE Profile" or
GE® appliance questions, visit our website at #`
ge.com or call GE Answer Center® service,
800.626.2000.
z
Listed by
Underwriters z
imagination at work Laboratories
r
Specification Created 6/08 150049
ZBD187ONSS
GE Monogr9 m° 18" Dishwasher
Dimensions and Installation Information (in Inches)
• The dishwasher must be installed so that the drain hose is
no more than 10 feet in length for proper drainage.
• The dishwasher must be full encl sed on the top, sides
34'm35• 2,V and back, and must not support any part of the enclosure.
Underside of Min
m" � CLEARANCES: '
I
Cabinets When installed into a corner, allow 2"
Square min. clearance
6 and between dishwasher and adjacent cabinet,wall or other
s
j
174T Min. Plumb appliances. Allow 25 -5/8" min. clearance from the front of
the dishwasher for door opening.
Floor MUST
be Even with J
flaom F1oa j
32 -1/Y
Admtalk Countertop
to 35' t
Dishwasher a
22 -1/2' Max.
17 -1/2'
ADA- Compliant ZBD1870NSS:
25 -5/8"
Installation below 34" -high countertops
A reduced - height installation (32 -112" min.) beneath a Clearance for Door
34" countertop can be accomplished by removing the Opening 2" Minimum
front leveling legs. The rear legs should be screwed in
flush with the bottom support, as shipped. The front of
the dishwasher must. be shimmed to level it. Water and
electrical must be routed through the back wall. Installation Information: I
Before installing, consult installation instructions packed
Electrical Requirements with product, or available at Monogrom.com, for current
dimensional data.
The dishwasher must be supplied with 120V, 60Hz, and s
connected to an individual properly grounded branch
circuit protected by a 15- or 20 -amp circuit breaker or
time -delay fuse.
i
[[
F
t
b
For answers to your Monogram ®GE Profile`" or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
AAAW�k U Listed by As an ENERGY STAR•
rw
Underiters ®partner GE has determined
® Laboratories ' that this product meets the
imagination at work zn ENERGY STAR guidelines F
for energy efficiency.
Specification Created 6/08 150049