11 May 2010
Catawba Coutnt Plan Review ~L
"16 North Center Street C fi PIS ~'t °
Hickory, North Carolina 28601
Re: BLDG-4-10-6619 - Alterations to 521 5W H1NY -10 B (CitiTrends) -
Comment Response
Commenter: Building Review
1. Sheet A-1: The current accessibility code...
2. Verify the project is fully accessible including parking...
3. Sheet A-3: Provide vertical grab bars to comply...
4. Sheet A-3: Provide an elevation drawing for the accessible df...
5. Sheet A-3: Provide details for the water heater...
6. Sheet A-3: Plumbing Note 10: Water piping installed in unconditioned...
'1. Sheet A-3: The 1 Y2 wet vent for the water closets downstream...
5. Sheet A-4: Provide specification for the new bathroom exhaust fan...
Cl. Sheet A-1: Per Section 1014.2 of the 2009 NO Bldg Code egress...
10.5heet A-1: Provide means of egress illumination for exit discharge...
11. Sheet A-1: Verify compliance with Article 210.62 of the 2005 NEG...
Architect's Response:
1. Cover sheet / applicable codes have been updated
2. Project is to be fully accessible. Existing handicapped parking
directly in front of store is to remain, the storefront canopy
sidewalk is flush with the parking lot, therefore a ramp is not
needed. Accessible drinking fountain and bathrooms are also
provided. Existing area of rescue at rear exit, including existing
intercom and emergency lighting to remain.
3. Vertical grab bar is now shown on 2/A-3 (FYI your comment referred
to 601.4.1.2.2 which are the tub requirements rather than (504.5.1
for the toilet grab bars but the request was understood).
4. Drinking fountain Elevations are now shown as detail '1/A-3
5. Water heater isometric detail now shown on detail 6/A-3
6. Plumbing note #10 on A-3 has been updated
'i. Riser Diagram has been revised to show 2" wet vent
Continued...
s
5. Exhaust fan specifications now included in fixture key
Cl. Egress through intervening space:
a. Stock hazard is of same hazard as main retail area
b. No more than 50% of exit access is through the stockroom
c. Stockroom is not subject to locking from egress side
d. A 44" wide aisle through the stockroom is now depicted as well
as a railing system to provide physical demarcation.
10.Existing egress illumination at rear exit discharge area of rescue
was not previously shown, but will remain. YVe have also added a note
to the fixture key to clarify to the contractor that they must verify
F that the lights will meet the 1 footcandle requirement at floor level of
the egress route.
11. Three receptacles have been added at the show window area to
meet 210.62 of the 2005 NEC.
I
Respectfully,
Brian Kolis
for
A. Craig Ydaldron, Architect
L
C
gGg'
f'
1
r
r
A. CRAIG NALDRON, ARCHIT T -77
ARCHITECTURE - SPACE PLANNING - CONSUL [ C/
n
4939 LOWER R05WELL ROAD, SUITE 103 MARIETTA, GE li 30065
F: ?10-5-78-3300 F: -7-70-5'78-0-1-70 MAY 14
2010
ANSM i !
ter i M 0
11 May 2010
City of Hickory, NO / Catawba County
Development Assistance Center
76 North Center Street
Hickory, North Carolina 25601
-v °Z
Attention: Plan Review
RE: CITi TREN17s - TENANT UPFIT - HirKoRY PLAzA (BLDG-4-10-6619 )
YVE ARE 5ENDING YOU THE FOLLonNG: ATTACHED
/ , _ t r r
VIA: UF5
Copies Description
5 Sets 5i ned 6 sealed construction documents (revised)
1 Architect's Comment response
1 Check in amt of $10.00 for processing fee
Memo:
Please find enclosed Five full sets of revised documents of the Citi
Trends Tenant Fit-up at Hickory Plaza for re-review. The fire comments were
not addressed since they were previously approved as noted. If you have any
questions or comments please feel free to call us at the number above or email
us at bk@pcarchitects.com or cwapcarch itects.com
Thank you,
Brian K0115
For A. Craig YValdron, Architect
01
r