HomeMy WebLinkAboutAUTH-11-2018-107570.tif David Currier I Customer Number: #C8015
Owner of: LAKE NORMAN ,- t
LAKE NORMAN SEWER AND SEPTIC � i ' !� l✓f
PO BOX 889EW E
Date of Inspection:
Denver, NC 28037 S
p� 7/6/22
(704)-483-5125 O[License Number:995940 SEPTI ®Initial ❑6 Months
0
Subsurface Wastewater Inspection Form Lot Number:
Name & Address of Owner:
BRENDA WICKWIRE
6852 LOCKE DRIVE . -
SHERILLS FORD, NC 28673 PUMP: TYPE OF SYSTEM:
Pump Model: ®Type IV
SEPTIC TANK: Pump HP:
(50% reduction)
Pump Voltage: 120 V
Size of Septic Tank: 1000 Gallons. ❑Type III
Size of Pump Tank: 1000 Gallons. ®High water alarm operating (25% reduction)
properly ❑LPP OR ❑DRIP
® Risers Readily Accessible
®Pipework in good condition
Z No Signs of Infiltration ❑Gravity Septic
®Control Panel in Good Condition
® Structurally Sound Location of Control Panel ❑Pump to Gravity
® Filter(s) Cleaned ❑Wall ®Post ----" inches High
®Surface Water Diverted at System ®Control floats operating properly
REDUCTION TYPE:
Scum Level: 4" ®Effluent free & clear of solids
El Polystyrene
Sludge Level: 7"
Scum plus Sludge level: 11" ❑Chamber
Liquid Depth: 50" Head Settings: ®Other
02' ❑ 3' ❑other
TANK NEEDS PUMPING: EYES ® NO
Field Location: ®Onsite ❑ Offsite DISTRIBUTION TYPE: ®No effluent surfacing
®Manifold ® Traffic Protected
Notes and/or Corrective Action Needed: OD-Box ®Surface Water Diverted
At this time the septic system is functioning ❑Serial ®Line Cover Maintained
properly. The tank doesn't need to be Lines ---- X Ft long ®Distribution Set
pumped. We do recommend applying some EACH= ---- Ft Line. ® Repair Area Reserved
bacteria to septic tank. Thank you! ❑Varies
LOW PRESSURE SYSTEM:
®Turn-ups, Clean-Outs, Valves Located/ Protected
®Laterals Free of Excess solids
,,, � ' ®Laterals Flushed
INSPECTOR SIGNATURE:
F Pressure Head Setting fnr Fach I ine
.) -f-k• - I I- fg.Q - Io
David Currier Date of Inspection:
Owner of: LAKE NORMAN 7/23/25
:_AKE NORMAN SEWER AND SEPTIC
PO BOX 889 ®Initial ❑6 Months
Denver, NC 28037
(704)-483-5125 ..
Field location
License Number: 995940
sEpiric
EOnsite ❑ Offsite
Subsurface Wastewater Inspection Form Offsite septic lot#:
Name & Address of Owner: nntrol panel:
Todd & Brenda Wickwire YPE OF F SYSTEM:
Conduit sealed: DYES ❑ NO
6852 Locke Drive ❑Polystyrene
Sherrills Ford, NC 28673 Alarm operating: ®YES ❑ NO ❑Chamber
Panel location: ❑Panel ❑LPPBS
SEPTIC TANK:
❑Wall ®Post 36" inches High
❑Gravel ELPP
Size of Septic Tank: 1000 Gallons
Counter- Cycle: n/a Hour: n/a ❑Large diameter pipe
Risers Readily Accessible: ®YES ❑ NO ❑Other:
Signs of Infiltration: DYES E NO REDUCTION TYPE:
PUMP Tank:
Structurally Sound: ®YES ❑ NO ®Type IV(50%reduction)
Size of Pump Tank: 1000 Gallons
Filter(s) Cleaned: ®YES ❑ NO ❑Type III(25%reduction)
Pump Model:
Surface Water Diverted: DYES ❑ NO ❑ None
Pump HP:
Scum Level: 6" Pump Voltage: 120v
lead Settings:
Sludge Level: 6" Pipework in good condition: ®YES ❑NO
Scum plus Sludge level: 12" ®2' ❑ 3' ❑other:
Liquid Depth: 50" Control floats operating: ®YES ❑ NO
Distribution Set @ inspection:
TANK NEEDS PUMPING: OYES ® NO Effluent free &clear of solids: ®YES ❑ NO ®YES ❑NO
TANK NEEDS PUMPING: EYES ® NO Drain field:
Effluent surfacing:OYES E NO
idotes and/or Corrective Action Needed: Traffic Protected:®YES ❑NO
We performed your 15t Type IV inspection. We Repair Area Reserved:
removed and cleaned the outlet filter. We DISTRIBUTION TYPE: EYES ❑NO
Surface Water Diverted:
purged out the drain field lines and reset the ®Manifold ❑Individual valves ®YES ❑NO
head pressures. Dropped off a lyear supply of Line Cover Maintained:
Lenzyme. Thanks! ❑Serial/drop boxes ❑Distribution box OYES ❑NO
LOW PRESSURE SYSTEM: Pump draw down:
Turn-ups and/or Valves Located/ Gallons per cycle:
Protected:®YES ❑NO Draw down length:
F Laterals Free of Excess solids:EYES ❑NO Tether length if wide angle
INSPECTOR SIGNATURE;
�'.G' ����= % Laterals Flushed:EYES ❑NO float:
aucfh -I I-4OR - (o3Y37)0
David Currier Date of Inspection:
Owner of: LAKE NORMAN 1/22/26
LAKE NORMAN SEWNFP AND SEPT!
PO BOX 889SIEWE ❑Initial ❑x 6 Months
Denver, NC 28037 p�
(704)-483-5125 OC ��.��
License Number:995940SEP1rIC Field location:
®Onsite ❑ Offsite
Subsurface Wastewater Inspection Form Offsite septic lot#:
Name & Address of Owner: Control panel:
Todd & Brenda Wickwire TYPE OF SYSTEM:
6852 Locke Drive Conduit sealed: EYES ❑ NO
❑Polystyrene
Sherrills Ford, NC 28673 Alarm operating: EYES ❑ NO ❑Chamber
Panel location: ❑Panel ❑LPPBS
SEPTIC -TANK:
❑Wall ®Post 36" inches High
Size of Septic Tank: 1000 Gallons ❑Gravel ❑LPP
Counter- Cycle: n/a Hour: n/a ❑Large diameter pipe
Risers Readily Accessible: DYES ❑ NO ❑Other:
Signs of Infiltration: DYES ® NO REDUCTION TYPE:
PUMP Tank:
Structurally Sound: ®YES ❑ NO ®Type IV(50%reduction)
Size of Pump Tank: 1000 Gallons
Filter(s) Cleaned: ®YES ❑ NO ❑Type III (25%reduction)
Pump Model:
Surface Water Diverted:_EYES ❑ NO ❑ None
Pump HP:
Scum Level: 12" Pump Voltage: 120v
Head Settings:
Sludge Level: 3" Pipework in good condition: EYES ❑NO
Scum plus Sludge level: 15" ®2' ❑ 3' ❑other:
Liquid Depth: 50" Control floats operating: EYES ❑ NO
Distribution Set @ inspection:
TANK NEEDS PUMPING: ®YES ❑ NO Effluent free&clear of solids: ®YES ❑ NO EYES ❑NO
TANK NEEDS PUMPING: EYES ® NO Drain field:
Effluent surfacing:OYES E NO
Notes and/or Corrective Action Needed: Traffic Protected:®YES ❑NO
Repair Area Reserved:
We performed your 2nd Type IV inspection for DISTRIBUTION TYPE: EYES ❑NO
2025. We removed and cleaned the outlet Surface Water Diverted:
filter. The techs noted that the septic tank ®Manifold ❑Individual valves EYES ❑NO
Line Cover Maintained:
should be pumped. If you have any questions ❑Serial/drop boxes ❑Distribution box EYES ❑NO
please give our office a call. Thank you!
LOW PRESSURE SYSTEM: Pump draw down:
Turn-ups and/or Valves Located/
Gallons per cycle:
Protected:EYES ❑NO Draw down length:
(14,!0.../
Laterals Free of Excess solids:EYES ❑NoTether len th if wide an le
` �:'�' � Laterals Flushed:EYES ❑NO g gINSPECTOR SIGNATURE. float: