HomeMy WebLinkAboutAUTH-08-2018-103885.TIF eACONA /11956� The;lea'leader. AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693-Email: aqwatammysanders@gmail.com Customer Name: Krajack Date of Inspection: 8/30/2022 Address: Krajack-8852 Dogleg Road Sherrill Ford,NC 28673 Arrival Time: 12:41:00 PM System AX ID: AX-147941 Departure Time: 1:45:00 PM County: Catawba Permit No. Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or D-BOX Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 3 Scum 10 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 5;:..r. 6 Sludge Scum Sludge Tank Inspection Questions Tank 1 Tank 2 Clean Effluent Filter. Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect TanIRiser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recirculation Pumps Recirculation Pump 1 Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 0.8 Dose 10 Rest 49093 CT 2009.7 ETM Dose Pumps Pump 1 Tmer Settings Pump 1-Counters and Elapsed lime Meters Demand Dose Demand Rest 1782 CT 93.8 ETM Verify Conduit Seal: Verified AX-RT Treatment Pod Inspection Pod inspection .Pod 1 Inspect for Pending or Bridging: None Check and Record PSI: 4.5 Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record PSI 4.5 Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or DBOX Recirculation Chamber Inspection Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum t Sludge 0 Scum 0 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Property Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 rrEN 9Y, r :7 S:. After Disconnecting Power,Clean or Replace Bulb As Needed: Replaced Flush Housing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: Scum Sludge 0 Scum 0 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Cleaned Delivery Rate at Start Up: Unknown Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified LPP or P-Manifold or DBOX Inspection Areas Mowed and Clear of Obstruction: Yes Flush Laterals: Flushed Area Free of Ponding or Surface Effluent: Yes Set and Record Head Pressure: 3 ft Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly Current Delivery Rate: 26.4 Pump Efficiency: Return Valves and Control Panel to proper settings Done Control Panel Communication Checked: Panel called in. Inspection Notes 34-06=12x4.4=52.8+2=26.4 Paul Smith Operator Operators Signature F AQWA The clear leader. AQWA Inc. 1 )13S'� 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693— Email: aqwatammysanders@gmail.com Customer Name: Krajack Date of Inspection: 2/22/2023 Address: Krajack-8852 Dogleg Road Sherrill Ford,NC 28673 Arrival Time: 9:50:00 AM System AX ID: AX-147941 Departure Time: 12:30:00 PM County: Catawba Permit No. Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or D-BOX Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 2 Scum 6 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 Scum 14 Sludge Scum Sludge Tank Inspection Questions "; Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recirculation Pumps Recirculation Pump 1 Pump 1 Timer Settings Pump 1-Counters and Elapsed lime Meters 0.8 Dose 10 Rest 70392 CT 2297.5 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed lime Meters Demand Dose Demand Rest 1959 CT 102.6 ETM Verify Conduit Seal: Verified AX-RT Treatment Pod Inspection Inspect for Ponding or Bridging: None Check and Record PSI: 4.5 Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean.Brush,Flush Lateral: Done Recheck and Record PSI 4.5 Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or DBOX Recirculation Chamber Inspection Verify Inlet Flow: No Inflow I Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 0 Sludge 0 Scum 12 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Pumped Verify Audible Alarm Works for High Water float: Works Properly Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 I UV Disinfectant Unit Inspection UV 1 UV2 Atter Disconnecting Power,Clean or Replace Bulb As Needed: Cleaned Flush Housing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: Scum Sludge 0 Scum 0 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Cleaned Delivery Rate at Start Up: Unknown Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified LPP or P-Manifold or DBOX Inspection Areas Mowed and Clear of Obstruction: Yes Flush Laterals: See Notes Area Free of Ponding or Surface Effluent: Yes Set and Record Head Pressure: N/A Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Repair Needed Current Delivery Rate: Pump Efficiency: Return Valves and Control Panel to proper settings Done Control Panel Communication Checked: Panel called In. Inspection Notes Distribution valve box has leak between pvc Ts.Was unable to get accurate dose pump flow data for distribution field.Will have to rebuild a manifold at the shop and return with it.The installer for this system built this manifold with all pvc Ts butted up to each other,so there is no way to repair the leak without rebuilding the entire manifold.Will have to return with replacement equipment. Paul Smith Operator Operators Signature AOWA J)nh cs5 The cleat leader. l AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693—Email: aqwatammysanders@gmail.com Customer Name: Krajack Date of Inspection: 8/16/2023 Address: Krajack-8852 Dogleg Road Sherrill Ford,NC 28673 Arrival Time: 7:45:00 AM System AX ID: AX-147941 Departure Time 9:45:00 AM County: Catawba Permit No. Inspection and Maintenance Checklist-AX-RT with I PP or P-Manifold or D-BOX Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 2 Scum 6 Sludge Scum Sludge Tank 1 Outlet Readings lank 1 Outlet Readings 0 Scum 6 Sludge Scum Sludge '',, y, Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recirculation Pumps Recirculation Pump 1 Pump 1 Tmer Settings Pump 1-Counters and Elapsed Time Meters 0.8 Dose 10 Rest 92235 CT 2591.8 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters Demand Dose Demand Rest 110.1 CT 2159 ETM Verify Conduit Seal: Verified AX-RT Treatment Pod inspection Inspect for Ponding or Bridging: None Check and Record PSI: 5 Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record PSI 5 Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or DBOX • Recirculation Chamber Inspection . Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 0 Sludge 0 Scum 1 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Property Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 After Disconnecting Power,Clean or Replace Bulb As Needed: Replaced Flush Housing Thoroughly: Flushed Retum Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: Scum Sludge 0 Scum 0 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Cleaned Delivery Rate at Start Up: Unknown Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified LPP or P-Manifold or DBOX Inspection Areas Mowed and Clear of Obstruction: Yes Flush Laterals: Flushed Area Free of Ponding or Surface Effluent: Yes Set and Record Head Pressure: 3 ft Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly Current Delivery Rate: 35.2 Pump Efficiency: Return Valves and Control Panel to proper settings Done Control Panel Communication Checked: Panel called In. Inspection Notes 37-45=8 x4.4=35.2 Paul Smith Operator Operators Signature aull\ eAQWA The clear leader. AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone:252-243-7693—Email:aqwatammysanders@gmail.com Customer Name: Krajack Date of Inspection: 3/25/2025 Address: Krajack-8852 Dogleg Road Sherrill Ford,NC 28673 Arrival Time: 9:45:00 AM System AX ID: AX-147941 Departure Time: 1:00:00 PM County: Catawba Permit No. Inspection and Maintenance.Checklist-AX-RT with LPP or P-Manifold or D-BOX Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 3 Scum 14 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 Scum 8 Sludge Scum Sludge Tank Inspection Questions Tank 1 Tank 2 Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recirculation Pumps Recirculation Pump'1 Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 0.8 Dose 10 Rest 67744 CT 3610.4 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters Demand Dose Demand Rest 3211 CT 151.1 ETM Verify Conduit Seal: Verified AX-RT Treatment Pod Inspection Pod Inspection Pod 1 Inspect for Ponding or Bridging: None Check and Record PSI: 5 Verify Orifice Position and Assess for Clogging: Ok Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record PSI 5 Flush Pod Throroughly: Done Inspect and Clean Vents: Vents Clear Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or DBOX Recirculation Chamber Inspection _ _ Verify Inlet Flow: No Inflow Inspect Liquid: High Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 2 Sludge 0 Scum 2 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 UV Disinfectant Unit Inspection UV 1 UV2 After Disconnecting Power,Clean or Replace Bulb As Needed: Cleaned Flush Housing Thoroughly: Flushed Retum Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Turbidity Reading: 10.35 Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: Scum Sludge 0 Scum 1 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: Unknown Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified LPP or P-Manifold or DBOX Inspection Areas Mowed and Clear of Obstruction: Yes Flush Laterals:,Flushed Area Free of Ponding orSurface Effluent: Yes Set and Record Head Pressure: 3 ft Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly Current Delivery Rate: 35.2 Pump Efficiency: Retum Valves and Control Panel to proper settings Done Control Panel Communication Checked: Panel called in Inspection Notes Textile missing upon arrival,retrieved from bottom of POD and placed back into position.Spin aerator assembly detached from 1 bracket support, reattached assembly.Replaced 6 inch lid clean out at distribution box. Recommended to owner not to let mower wheels ride directly on cap,the ground is soft.33.5141.5=8x4.4=35.2 Paul Smith Operator Operators Signature OA 001c3- - 0-3R R3-- AQWK The clear leader. AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone:252-243-7693—Email:aqwatammysanders@gmail.com Customer Name: Krajack Date of Inspection: 10/23/2025 Address: Krajack-8852 Dogleg Road Sherrill Ford,NC 28673 Arrival Time: 11:45:00 AM System AX ID: AX-147941 Departure Time: 1:15:00 PM County: Catawba Permit No. Inspection and Maintenance Checklist-<AX-RTwith LPP or P-Manifold or D-BOX Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 5 Scum 5 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 Scum 9 Sludge Scum Sludge Tank Inspection Questions Tank 1 Tank Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recirculation Pumps Recirculation Pump 1 Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 0.8 Dose 10 Rest 91891 CT 3936.1 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters Demand Dose Demand Rest 164.5 CT 3570 ETM Verify Conduit Seal: Verified AX-RT Treatment.Pod Inspection podinspection, Pod') 4_. Inspect for Ponding or Bridging: None Check and Record PSI: Verify Orifice Position and Assess for Clogging: Ok Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record PSI Flush Pod Throroughly: Done Inspect and Clean Vents: Vents Clear Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or DBOX III I Recirculation Chamber Inspection Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 3 Sludge 0 Scum 1 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified Ultraviolet Disinfection Unit,lnspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 UV Disinfectant Unitlnspectiotf UV 1. -UV2' After Disconnecting Power,Clean or Replace Bulb As Needed: Replaced Flush Housing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage:- None Seen Turbidity Reading: 0.85 Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: Scum Sludge 0 Scum 4 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: Unknown Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified ,LPP or P-Manifold or DBOX Inspection Areas Mowed and Clear of Obstruction: Yes Flush Laterals: Area Free of Ponding or Surface Effluent: Yes Set and Record Head Pressure: Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly Current Delivery Rate: 35.2 Pump Efficiency: Return Valves and Control Panel to proper settings Done Control Panel Communication Checked: Called in healthy. Inspection Notes - 40-52=8x4.4=35.2 SEPTIC TANK needs to be pumped out. Christopher Sanders C _A Operator Operators Signature