HomeMy WebLinkAboutAUTH-07-2018-103201.TIF 00,A.-14\ c� c�� - iuu David Currier Date of Inspection: Owner of: LAKE NORMAN 7/28/25 LAKE NORMAN SEWER AND SEPTIC PO BOX 889 ®Initial 06 Months ...,SEWE Denver, NC 28037 (704)-483-5125 « 111.11111 Field location: License Number:995940 SEPTIC ®Onsite ❑ Offsite Subsurface Wastewater Inspection Form Offsite septic lot#: Name & Address of Owner: 7ontrol panel: Beverly Greve -YPE OF SYSTEM: 8254 Nolley Lane Conduit sealed: ®YES LINO Sherrills Ford, NC 28673 Alarm operating: ®YES El NO ❑Polystyrene ❑Chamber Panel location: ®Panel ELPPBS SEPTIC TANK: ❑Wall ®Post 12"inches High Size of Septic Tank: 1000 Gallons ElGravel ❑LPP Counter- Cycle: Hour: ❑Large diameter pipe Risers Readily Accessible: ®YES ❑ NO ❑Other: Signs of Infiltration: OYES ® NO SEDUCTION TYPE PUMP Tank: Structurally Sound: ®YES Cl NO ®Type IV(50%reduction) Size of Pump Tank: 1000 Gallons Filter(s)Cleaned: ®YES El NO ❑Type III(25%reduction) Pump Model: Zoeller Surface Water Diverted: DYES ❑ NO Pump HP: N/A ❑ None Scum Level: 2" Pump Voltage: 120v ' ad Settings. Sludge Level: 4" Pipework in good condition: EYES ❑NO Scum plus Sludge level: 6" Z2' ❑ 3' ❑other: Liquid Depth:40" Control floats operating: ®YES ❑ NO Distribution Set @ inspection: TANK NEEDS PUMPING: DYES E NO Effluent free&clear of solids: ®YES ❑ NO EYES ❑NO TANK NEEDS PUMPING: LIVES ® NO Drain field: Effluent surfacing:OYES E NO Notes and/or Corrective Action Needed: Traffic Protected:EYES ❑NO Repair Area Reserved: DISTRIBUTION TYPE: EYES ❑NO Surface Water Diverted: I:Manifold ❑Individual valves EYES ❑NO Line Cover Maintained: ElSerial/drop boxes ❑Distribution box EYES ❑NO LOW PRESSURE SYSTEM: Pump draw down: Turn-ups and/or Valves Located/ Gallons per cycle: Protected:DYES ❑NO Draw down length: (dej 1 Laterals Free of Excess solids:EYES ❑NoTether length if wide angle INSPECTOR SIGNATURE: C�d �" Laterals Flushed:EYES ❑No float: David Currier Date of Inspection: Owner of: LAKE NORMAN 1/21/26 LAKE NORMAN SEWER AND SEPTIC PO BOX 889 ❑Initial ❑X6 Months SEwEik Denver, NC 28037 (704)-483-5125 SEPTIC' Field location: License Number:995940 ®Onsite ❑ Offsite Subsurface Wastewater Inspection Form Offsite septic lot#: Name & Address of Owner: Beverly Greve TYPE OF SYSTEM: Conduit sealed: ®YES ❑ NO 8254 Nolley Lane ❑Polystyrene Sherrills Ford, NC 28673 Alarm operating: DYES ❑ NO ❑Chamber Panel location: ®Panel ❑LPPBS EWall ®Post 12" inches High Size of Septic Tank: 1000 Gallons ❑Gravel ❑LPP Counter- Cycle: Hour: ❑Large diameter pipe Risers Readily Accessible: ®YES ❑ NO ❑Other: Signs of Infiltration: DYES ® NO - SEDUCTION TYPE: PUMP Tank: Structurally Sound: EYES ❑ NO ®Type IV(50%reduction) Size of Pump Tank: 1000 Gallons Filter(s) Cleaned: ®YES El NO ❑Type III(25%reduction) Pump Model: Zoeller Surface Water Diverted: ®YES ❑ NO ❑ None Pump HP: N/A Scum Level: 3" Pump Voltage: 120v dead Settings: Sludge Level: 6" Pipework in good condition: ®YES ❑NO Scum plus Sludge level: 9" (02' ❑ 3' Dother: Liquid Depth:40" Control floats operating: ®YES ❑ NO Distribution Set @ inspection: TANK NEEDS PUMPING: EYES ® NO Effluent free&clear of solids: EYES ❑ NO EYES ❑NO TANK NEEDS PUMPING: EYES Z NO Drain field: Effluent surfacing:LIVES (E NO Notes and/or Corrective Action Needed: Traffic Protected:®YES ❑NO We have completed your 2"d inspection for the Repair Area Reserved: year 2025.At the time of the inspection the DISTRIBUTION TYPE_ (EYES ❑NO system was functioning as intended. We Surface Water Diverted: ®Manifold ❑Individual valves ®YES ❑NO removed and cleaned the outlet filter and saw Line Cover Maintained: no further issues at this time. Thank you! ❑Serial/drop boxes ❑Distribution box ®YES ❑NO LOW PRESSURE SYSTEM: Pump draw down: Turn-ups and/or Valves Located/ Gallons per cycle: Protected:®YES ❑NO Draw down length: p ��7/„ Laterals Free of Excess solids:®YES ❑NO Tether length if wide angle INSPECTOR SIGNATURE: float: Laterals Flushed:®Yes ❑NO float: