r • 0 TCW WASTEWATER 704.776.4443 www.TCW waslowaler.com 4/21/2022 Michael Adams 2204 Metcalf Dr. Sherrills Ford. NC 28673 — iOJ-43 RE: Inspection Report for 2204 Metcalf Dr.Sherrills Ford NC 28673 Dear Michael Adams: We are pleased to submit to you our electronic septic system inspection report for the work completed recently at your property.This report provides a summary of the work performed, a status update on any issues found, and includes recommendations specific to any issues requiring your attention. The first page provides you with a summary of the inspection performed. Pages 2-6 of the report provides additional information, if applicable,for each section of your wastewater system. We hope you will find this electronic summary report helpful in understanding the current status of your septic system. Detailed field notes are recorded and maintained in the office should you have any additional questions in regards to your inspection. We appreciate the opportunity to serve you. Sincerely, TCW Wastewater Management, Inc. 5600 Lakeview Road Charlotte.NC 28269 m 0 TCW WASTEWATER 704.7784443 www TCWwastnwntnr.coin Summary Michael Adams Inspection Date/Time: 04-19-2022 /11:15 AM 2204 Metcalf Dr. Technician: Alex Lamb Sherrills Ford NC 28673 System Type PPBPS Observations Seotic Tank Inspection Results: Action Recommended Septic Tank needs pumping: Yes Pump Tank Inspection Results: No action needed Pump Tank needs pumping: No Pressure Manifold Inspection Results: N/A Ground Absorption Inspection Results No action needed Toilet testing dye strips left at house. No Distribution Inspection Results: No action needed Bacteria packets left at house. No Status: Compliant Root killer was added today. No Note:If Action is Needed"on any of the above,please refer to the respective details section that follows this page. Recommendations Additional Notes: Septic tank needs to be pumped.Contact the office to schedule.Outlet pipe is still at a bad angle which puts the inlet pipe 1/2 underwater.This puts you at risk for a potential back up especially since the scum level is high.Contact the office for an estimate to repair.More details to follow this page. V . . I 10 ,' ' , t u- .i. : :'' `ice,. ..-.,-.,--I - S Y f r!- 4 . a r t. L W t� 4 >4� a • 6 Beginning inspection with dirty filtpr Ending Inspection r Septic Tank Inspection Results: Action Recommended Is there possible storm water infiltrating the No tank? Emergency tank storage(inches): Does the septic tank need pumping? Yes N/A Above water level(Optimum 8"—10") Date of last pumping: Filter screen clogging-%: 25% Scum level thickness(on top of water). a" Was the filter screen cleaned today? Yes Sludge level thickness(on bottom of tank): 8" Recommendations: The septic tank needs to be pumped.Outlet pipe is at a severe angle;this may put you at a potential risk for a back up.Recommend correcting. Notes: Septic tank needs to be pumped.Contact the office to schedule.Outlet pipe is still at a bad angle which puts the inlet pipe 1/2 underwater.This puts you at risk for a potential back up especially since the scum level is high.Contact the office for an estimate to repair. ar.l�wm+NIA tJ Ix Jx.111 t +Ir IA4�nw..I N ti..l.WYn.ex tN 1�1111P 111111�11{{I{ 111111 1� :L\Lr. f ©3� x.„ m I �- ""L. n..•..... ..�... ...I�� �mn.na.•rumn :WWII,ILL... _ _ •1.nfL.v •i.Ki. \x ..mrynm.elir�i Lmt" . OS 1.�S I itd1 ?_ • F ;11- nlet Sludge Level and Clean Filter Pump Tank Inspection Results: No action needed Is there possible storm water infiltrating No into the tank? Does the pump tank need pumping? No Is the high water ALARM functioning Yes properly today? Date of last pumping: Is the effluent pump functioning today? Yes Daily wastewater dispersed: Are the electrical controls in good (If available,calculated through pump run condition? N/A time.Optimum<250 GPO) Scum level thickness(on top of water): 0" Is the pump delivery rate within the acceptable range today? Yes Sludge level thickness(on bottom of tank): 1" Recommendations: Notes: r Pressure Manifold Assembly Inspection Results: N/A Is the vault is in good condition? N/A Are the valves and pipes in good N/A condition? Is there evidence of clogging in the N/A discharge lines? Recommendations Notes I/ _It . ": 4 1 ---- 1_ ' _„_ ilk, I i �._ 7-• Ground Absorption Field Inspection Results: No action needed Is there evidence of effluent surfacing? No Is the location of the absorption field Are there low or settled areas in the field On-site or Off-site? Offsite No that need fill-in? Is the vegetative covering over the field Yes maintained adequately. Recommendations: Notes: Low Pressure Distribution Inspection Results: No action needed Are the adjustment valves accessible? Yes Are the end of the laterals accessible? Yes Is each distribution lateral set with the proper pressure today? Not Evaluated Were all the system laterals flushed today? No Do the distribution laterals need cleaning or pressure jetting? No Recommendations Notes FIN 1SMEli (:RA1 F F1111:1Rt::J GRACE VALVE All LVOR L.A'1'E(•.A{. i'RC'{'F:(,T:' ' "TURN-UP f:RAnF. T�: RADF. N'{';1/ FC .•tl�;�T.� HIl(:KF.T �a .:•-i ' — • > ••••O•••:•O O O•e • O : :�e�at• Vie. tE TAL -A19E BLOCK SY.ST£M Panel Block System Low Pressure Pipe System