HomeMy WebLinkAboutAUTH-06-2018-101096.TIF I Customer Number:David Currier #C7794 Owner of: LAKE NORMAN LAKE NORMAN SEWER AND SEPTIC 1111/11A-0- 11 Po BOX 889 ..SEWE Date of Inspection: Denver, NC 28037 2/28/2022 (704)-483-5125 & �r SEP1I1r • License Number: 995940 ®Initial C6 Months Subsurface Wastewater Inspection Form Lot Number: Name & Address of Owner: TERRY ROGERS 2517 CAMELIA POINTE DRIVE SHERRILLS FORD, NC 28673 PUMP: TYPE OF SYSTEM: Pump Model: ZOELLER ®Type IV SEPTIC TANK: Pump HP: (50% reduction) Pump Voltage: 120V Size of Septic Tank: 1000 Gallons. ❑Type III Size of Pump Tank: 1000 Gallons. ®High water alarm operating (25% reduction) properly ❑LPP OR ❑DRIP ® Risers Readily Accessible ®Pipework in good condition ® No Signs of Infiltration CI Gravity Septic ®Control Panel in Good Condition ® Structurally Sound Location of Control Panel ❑Pump to Gravity ® Filter(s) Cleaned ❑Wall ®Post 17" inches High ®Surface Water Diverted at System ®Control floats operating properly REDUCTION TYPE: Scum Level: 3" ®Effluent free & clear of solids ❑Polystyrene Sludge Level: 3" Scum plus Sludge level: 6" ❑Chamber Liquid Depth: 51" Head Settings: ❑Other ®2' El 3' Dother TANK NEEDS PUMPING: DYES ® NO Field Location: ®Onsite ❑ Offsite DISTRIBUTION TYPE: No effluent surfacing ®Manifold ® Traffic Protected Notes and/or Corrective Action Needed: OD-Box ®Surface Water Diverted We performed the 15t Type IV inspection for ❑Serial ®Line Cover Maintained the year 2022. At the time of the inspection Lines 3 X 90 Ft long EDistribution Set we pumped out the septic tank. At this time EACH= 270 Ft Line. ❑ Repair Area Reserved the system is functioning as intended. ❑Varies Thanks! LOW PRESSURE SYSTEM: ❑Turn-ups, Clean-Outs, Valves Located/ Protected El Laterals Free of Excess solids (d,„;) CI Laterals Flushed INSPECTOR SIGNATURE: -1Precciire Head Setting for Farh I ine David Currier I Customer Number: #C7794 Owner of: LAKE NORMAN LAKE NORMAN SEWER AND SEPTIC Po BOX 889 Date of Inspection: Denver, NC 28037 8/29/22 (704)-483-5125 License Number: 995940 SEPTI ❑Initial 06 Months Subsurface Wastewater Inspection Form Lot Number: Name & Address of Owner: TERRY ROGERS 2517 CAMELIA POINTE DRIVE SHERRILLS FORD, NC 28673 PUMP: TYPE OF SYSTEM: Pump Model: ZOELLER NType IV SEPTIC TANK: Pump HP: (50% reduction) Pump Voltage: 120V Size of Septic Tank: 1000 Gallons. EType III Size of Pump Tank: 1000 Gallons. ®High water alarm operating (25% reduction) properly ❑LPP OR ❑DRIP N Risers Readily Accessible N Pipework in good condition N No Signs of Infiltration ❑Gravity Septic ®Control Panel in Good Condition N Structurally Sound Location of Control Panel CI Pump to Gravity N Filter(s) Cleaned ❑Wall ®Post 17" inches High ®Surface Water Diverted at System ®Control floats operating properly REDUCTION TYPE: Scum Level: 2" N Effluent free & clear of solids Sludge Level: 2" ❑Polystyrene Scum plus Sludge level: 4" El Chamber Liquid Depth: 51" Head Settings: ❑Other N2' ❑ 3' Elother TANK NEEDS PUMPING: DYES N NO Field Location: ZOnsite ❑ Offsite DISTRIBUTION TYPE: NNo effluent surfacing NManifold N Traffic Protected Notes and/or Corrective Action Needed: ❑D-Box Surface Water Diverted At the 2nd inspection the septic system was ❑Serial ®Line Cover Maintained functioning as intended. We have completed Lines 3 X 90 Ft long ❑Distribution Set both inspections for the year 2022. Thanks! EACH= 270 Ft Line. ❑ Repair Area Reserved ❑Varies LOW PRESSURE SYSTEM: ❑Turn-ups, Clean-Outs, Valves Located/ Protected ❑Laterals Free of Excess solids Qf- Laterals Flushed INSPECTOR SIGNATURE. H PrPcci rP HPacl SPttina fnr Faeh I inp David Currier LAKE of Inspection: Owner of: LAKE NORMAN 12/3/24 LAKE NORMAN SEWER AND SEPTIC PO BOX 889SEINEEtk ❑Initial El Months Denver, NC 28037 pp.� (704)-483-5125 OC _ENNI 11 �' License Number:995940 SEPTIC Field location: ® ElOnsite ❑ Offsite Subsurface Wastewater Inspection Form Offsite septic lot#: Name&Address of Owner: Control panel: TERRY ROGERS TYPE OF SYSTEM: 2517 CAMELIA POINTE DRIVE Conduit sealed: ®YES DINO ❑Polystyrene SHERRILLS FORD, NC 28673 Alarm operating: ®YES 0 NO ❑Chamber Panel location: ®Panel ❑LPPBS SEPTIC TANK: ❑Wall ®Post 17"inches High Size of Septic Tank: 1000 Gallons ❑Gravel ❑LPP Counter- Cycle: Hour: ❑Large diameter pipe Risers Readily Accessible: DYES ❑ NO ❑Other: Signs of Infiltration: OYES El NO REDUCTION TYPE: PUMP Tank: Structurally Sound: ®YES 0 NO ®Type IV(50%reduction) Size of Pump Tank:1000 Gallons Filter(s)Cleaned: ®YES ❑ NO ❑Type Ill(25%reduction) Pump Model: Zoeller Surface Water Diverted: ®YES ❑ NO Pump HP: ❑ None Scum Level: 3" Pump Voltage: 115v Head Settings: Sludge Level: 7" Pipework in good condition:®YES 0 NO Scum plus Sludge level: 10" 1812' 0 3' Dother: Liquid Depth:51" Control floats operating: ®YES 0 NO Distribution Set @ inspection: TANK NEEDS PUMPING: OYES ® NO Effluent free&clear of solids: ®YES 0 NO OYES 0 NO TANK NEEDS PUMPING: DYES ® NO Drain field: Effluent surfacing:OYES ®NO Notes and/or Corrective Action Needed: Traffic Protected:®YES 0 NO We performed your 2nd Type IV inspection for Repair Area Used: the year.At the time of the inspection the DISTRIBUTION TYPE: OYES ®NO Surface Water Diverted: system was functioning as intended. We ®YES 0 NO ®Manifold ❑Individualvalves removed and cleaned the outlet filter. If you Line Cover Maintained: have any questions please contact our office. ❑Serial/drop boxes ❑Distribution box ®YES ❑NO Thank you! LOW PRESSURE SYSTEM: Pump draw down: Turn-ups and/or Valves Located/ Gallons per cycle:212 Protected:®YES ❑NO Draw down length:10.6 Oa, Iv Laterals Free of Excess solids:®YES 0 NO ' L(/ f�O Laterals Flushed:®es ❑NO Tether length if wide angle INSPECTOR SIGNATURE. / float:10.1" David Currier Date of Inspection: Owner of: LAKE NORMAN 5/29/24 LAKE NORMAN SEWER AND SEPTIC PO BOX 889 Denver, NC 28037 p- ®Initial 06 Months (704)-483-5125 « c7 Field location: License Number:995940 ®Onsite 0 Offsite Subsurface Wastewater Inspection Form Offsite septic lot#: Name&Address of Owner: Control panel: TERRY ROGERS TYPE OF SYSTEM: 2517 CAMELIA POINTE DRIVE Conduit sealed: ®YES 0 NO ❑Polystyrene SHERRILLS FORD, NC 28673 Alarm operating: ®YES 0 NO ❑Chamber Panel location: ®Panel ❑LPPBS SEPTIC TANK: ❑Wall ElPost 17"inches High Size of Septic Tank: 1000 Gallons ❑Gravel ❑LPP Counter- Cycle: Hour: ❑Large diameter pipe Risers Readily Accessible: OYES 0 NO ❑Other: Signs of Infiltration: DYES CO NO REDUCTION TYPE: PUMP Tank: Structurally Sound: ®YES 0 NO ®Type IV(50%reduction) Size of Pump Tank:1000 Gallons Filter(s)Cleaned: ®YES 0 NO ❑Type III(25%reduction) Pump Model: Zoeller Surface Water Diverted: ®YES 0 NO 0 None Pump HP: Scum Level: 2" Pump Voltage: 115v Head Settings: Sludge Level: 6" Pipework in good condition:EYES 0 NO Scum plus Sludge level:8" 1812' 0 3' Dother: Liquid Depth:53" Control floats operating:®YES 0 NO Distribution Set @ inspection: TANK NEEDS PUMPING: DYES El NO Effluent free&clear of solids: (OYES 0 NO EYES 0 NO ISWW TANK NEEDS PUMPING: DYES ® NO Drain field: Effluent surfacing:OYES ®NO Notes and/or Corrective Action Needed: Traffic Protected:®YES 0 NO We performed your 15t Type IV inspection for Repair Area Used: the year 2024.At the time of the inspection the DISTRIBUTION TYPE: OYES ®NO system operating as intended. The techs did Surface Water Diverted: ElManifold ❑Individualvalves ®YES 0 NO note the outlet pipe is slightly pitched upwards. Line Cover Maintained: We will be back out in 6 months to perform the ❑Serial/drop boxes ❑Distribution box EYES ❑NO 2nd inspection for the year.Thanks! LOW PRESSURE SYSTEM: Pump draw down: Turn-ups and/or Valves Located/ Gallons per cycle:212 Protected:®YES 0 NO Draw down length:10.6 GPI) Laterals Free of Excess solids:®YES 0 NO �J✓" Tether length if wide angle INSPECTOR SIGNATURE. Laterals Flushed:EYES 0 NO float:10.1" IA "off- 3q0 /0I(` David Currier Date of Inspection: Owner of: LAKE NORMAN 6/19/25 AKE NORMAN SEWER AND SEPTIC PO BOX 889 _SEW E Nlnitial ❑6 Months Denver, NC 28037 pp-� (704)-483-5125 OC SEPi�ield License Number:995940 location: NOnsite ❑ Offsite Subsurface Wastewater Inspection Form Offsite septic lot#: Name & Address of Owner: :ontrol panel: TERRY ROGERS YPE OF SYSTEM: 2517 CAMELIA POINTE DRIVE Conduit sealed: EYES ❑ NO SHERRILLS FORD, NC 28673 Alarm operating: EYES E NO ❑Polystyrene ❑Chamber Panel location: ElPanel ❑LPPBS )EPTIC TANK: ❑Wall ®Post 17"inches High Size of Septic Tank: 1000 Gallons ❑Gravel ❑LPP Counter- Cycle: Hour: ❑Large diameter pipe Risers Readily Accessible: ®YES ❑ NO ❑Other: Signs of Infiltration: DYES N NO REDUCTION TYPE: PUMP Tank: Structurally Sound: EYES ❑ NO ®Type IV(50%reduction) Size of Pump Tank: 1000 Gallons Filter(s) Cleaned: ®YES ❑ NO EType III(25%reduction) Pump Model: Zoeller Surface Water Diverted: DYES ❑ NO Pump HP: ❑ None Scum Level: 3" Pump Voltage: 115v lead Settings: Sludge Level: 8" Pipework in good condition: ®YES LINO Scum plus Sludge level: 11" N2' ❑ 3' ❑other: Liquid Depth: 51" Control floats operating: EYES ❑ NO Distribution Set @ inspection: TANK NEEDS PUMPING: DYES (8/ NO Effluent free&clear of solids: ®YES ❑ NO ®YES ❑NO TANK NEEDS PUMPING: EYES N NO Drain field: Effluent surfacing:OYES ®NO otes and/or Corrective Action Needed: Traffic Protected:®YES ❑NO We performed your ft Type lv inspection for Repair Area Used: the year 2025. We removed and cleaned the )ISTRIBUTION TYPE: OYES ®NO Surface Water Diverted: outlet filter. We purged out the drain field lines ®YEs ❑NO IN Manifold ❑Individual valves and reset the head pressures. At the time of the Line Cover Maintained: inspection the system was functioning as ❑Serial/drop boxes ❑Distribution box ®YES ❑NO intended. We will be back out in 6 months to OW PRESSURE SYSTEM: perform the 2nd inspection. lump draw down: Turn-ups and/or Valves Located/ Gallons per cycle:212 Protected:®YES ❑NO Draw down Iength:10.6 Laterals Free of Excess solids: YES® NO Tether length if wide angle INSPECTOR SIGNATURE: �'/'� v�J�✓�" Laterals Flushed:®YES ❑NO �� float:10.1 ILA - O6 - 0Ig- I010% David Currier Date of Inspection: Owner of: LAKE NORMAN 12/16/25 LAKE NORMAN SEWER AND SEPTIC PO BOX 889sEwER Denver, NC 28037 p-� ®Initial 06 Months (704)-483-5125 « f SEP1'1C- Field location' License Number: 995940 ® ®Onsite ❑ Offsite Subsurface Wastewater Inspection Form Offsite septic lot#: Name & Address of Owner: Control panel: TERRY ROGERS YPE OF SYSTEM: 2517 CAMELIA POINTE DRIVE Conduit sealed: EYES ❑ NO ❑Polystyrene SHERRILLS FORD, NC 28673 Alarm operating: EYES ❑ NO ❑chamber Panel location: ®Panel ELPPBS EPTIC TANK: ❑Wall ®Post 17"inches High Size of Septic Tank: 1000 Gallons ❑Gravel ❑LPP Counter- Cycle: Hour: ❑Large diameter pipe Risers Readily Accessible: ®YES ❑ NO ❑Other: Signs of Infiltration: OYES ® NO PUMP Tank: Structurally Sound: ®YES ❑ NO ®Type IV(50%reduction) Size of Pump Tank: 1000 Gallons Filter(s)Cleaned: EYES ❑ NO ❑Type III (25%reduction) Pump Model: Zoeller Surface Water Diverted: EYES ❑ NO ❑ None Pump HP: Scum Level: 2" Pump Voltage: 115v ead Settings: Sludge Level: 6" Pipework in good condition: ®YEs ❑NO Scum plus Sludge level:8" 02' ❑ 3' ❑other: Liquid Depth: 51" Control floats operating: ®YES ❑ NO Distribution Set @ inspection: TANK NEEDS PUMPING: DYES N NO Effluent free&clear of solids: ®YES ❑ NO ®YES ❑NO 1 TANK NEEDS PUMPING: EYES ® NO Drain field: '— Effluent surfacing:LIVES ®NO Jotes and/or Corrective Action Needer" Traffic Protected:®YES ❑NO We performed your 2nd Type IV inspection for Repair Area Used: the year 2025. We removed and cleaned the DISTRIBUTION TYPE: ®YES ❑NO outlet filter. We inspected the system and at Surface Water Diverted: ®Manifold ❑Individual valves ®YES ❑NO this time the system was functioning as Line Cover Maintained: intended. Thank you! ❑Serial/drop boxes ❑Distribution box ®YES ❑NO LOW PRESSURE SYSTEM: Pump draw down: Turn-ups and/or Valves Located/ Gallons per cycle:212 Protected:®YES ❑NO Draw down length:10.6 ' (it Laterals Free of Excess solids:®YEs ❑NO ,�," Tether length if wide angle INSPECTOR SIGNATURE. 2 Laterals Flushed:®YES ❑NO „ / float:10.1 V