Loading...
HomeMy WebLinkAboutAUTH-05-2018-100037.TIF I Customer Number: C7470 David Currier Owner of: LAKE NORMAN LAKE NORMAN SEWER AND SEPTIC /I if �`' J'�r Po BOX 889EWER Date of Inspection: Denver, NC 28037 s QQ-� 8/31/21 (704)-483-5125 OC License Number: 995940 SEPTINInitial ❑6 Months Subsurface Wastewater Inspection Form Lot Number: Name & Address of Owner: Jose Serrano 9408 Island Point Road Sherrills Ford, NC 28673 PUMP: TYPE OF SYSTEM: Pump Model: Goulds (WE0511HHV) ®Type IV SEPTIC TANK: Pump HP: 1/2hp (50% reduction) Pump Voltage: 115v Size of Septic Tank: 1500 Gallons. ❑Type HI Size of Pump Tank: 1500 Gallons. High water alarm operating (25% reduction) properly ELPP OR ❑DRIP ® Risers Readily Accessible M Pipework in good condition M No Signs of Infiltration ❑Gravity Septic ®Control Panel in Good Condition M Structurally Sound Location of Control Panel ❑Pump to Gravity ® Filter(s) Cleaned ®Wall ❑Post 5" inches High ®Surface Water Diverted at System ®Control floats operating properly REDUCTION TYPE: Scum Level: 2" M Effluent free & clear of solids Sludge Level: 0" ❑Polystyrene Scum plus Sludge level: 2" ❑Chamber Liquid Depth: 54" Head Settings: ®Other (LPP 02' ❑ 3' ❑other Distribution) TANK NEEDS PUMPING: OYES M NO Field Location: ®Onsite ❑ Offsite DISTRIBUTION TYPE: MNo effluent surfacing M Manifold M Traffic Protected Notes and/or Corrective Action Needed: ❑D-Box MSurface Water Diverted Our technicians performed the 1st Type IV CI Serial Line Cover Maintained inspection for the year. At the time of the Lines 6 X Ft long MDistribution Set inspection the system was functioning as EACH= ---- Ft Line. M Repair Area Reserved intended. Thank you! Varies LOW PRESSURE SYSTEM: ❑Turn-ups, Clean-Outs, Valves Located/ Protected ❑Laterals Free of Excess solids (/ '2 ' ❑Laterals Flushed INSPECTOR SIGNATURE: (Pressure Head Setting for Fach Line David Currier I Customer Number: C7470 Owner of: LAKE NORMAN LAKE NORMAN SEWER AND SEPTIC PO BOX 889 Date of Inspection: ..SEWE Ft Denver, NC 28037 3/16/2022 (704)-483-5125 OC `� • License Number:995940 ❑Initial ®6 Months C Subsurface Wastewater Inspection Form Lot Number: Name & Address of Owner: Jose Serrano 9408 Island Point Road Sherrills Ford, NC 28673 PUMP: TYPE OF SYSTEM: Pump Model: Goulds (WE0511HHV) Type IV SEPTIC TANK: Pump HP: 1/2hp (50% reduction) Pump Voltage: 115v Size of Septic Tank: 1500 Gallons. EType III Size of Pump Tank: 1500 Gallons. ❑High water alarm operating (25% reduction) properly El LPP OR ❑DRIP ® Risers Readily Accessible ❑Pipework in good condition ® No Signs of Infiltration El Gravity Septic ❑Control Panel in Good Condition ® Structurally Sound Location of Control Panel ❑Pump to Gravity ® Filter(s) Cleaned ®Wall ❑Post 5" inches High ®Surface Water Diverted at System ❑Control floats operating properly REDUCTION TYPE: Scum Level: 4" ❑Effluent free & clear of solids Sludge Level: 5" ❑Polystyrene Scum plus Sludge level: 9" ❑Chamber Liquid Depth: 54" Head Settings: ®Other (LPP 1:12' ❑ 3' ❑other Distribution) TANK NEEDS PUMPING: OYES ® NO Field Location: ®Onsite ❑ Offsite DISTRIBUTION TYPE: ®No effluent surfacing ®Manifold ® Traffic Protected Notes and/or Corrective Action Needed: ED-Box ®Surface Water Diverted At the time of the 2nd inspection the septic ESerial ®Line Cover Maintained system was functioning as intended. We Lines 6 X Ft long Distribution Set reset the head pressures and purged out the EACH= ---- Ft Line. ® Repair Area Reserved drain field lines. We've completed both ®Varies inspections for the year. Thanks! LOW PRESSURE SYSTEM: ®Turn-ups, Clean-Outs, Valves Located/ Protected ®Laterals Free of Excess solids /,:: :,::�" ®Laterals Flushed INSPECTOR SIGNATURE: 5 !Pressure Head Setting for Each Line autlik of - , 0 - David Currier Date of Inspection: Owner of: LAKE NORMAN 9/16/25 '.AKE NORMAN SEWER AND SEPTIC PO BOX 889 ...sEwErt ❑Initial ❑X6 Months Denver, NC 28037 0. (704)-483-5125 Ot sErric Field location: License Number:995940 ®Onsite ❑ Offsite Subsurface Wastewater Inspection Form Offsite septic lot#: Name & Address of Owner: :.ontrol panel: Jose Serrano TYPE OF SYSTEM: 9408 Island Point Road Conduit sealed: ®YES ❑ NO ❑Polystyrene Sherrills Ford, NC 28673 Alarm operating: ®YES ❑ NO ❑Chamber Panel location: ❑Panel ®LPPBS SEPTIC TANK: ®Wall ❑Post 30"inches High Size of Septic Tank: 1500+ 1000 Gallons ❑Gravel ❑LPP Counter- Cycle: n/a Hour: n/a ❑Large diameter pipe Risers Readily Accessible: EYES ❑ NO ❑Other: Signs of Infiltration: DYES ® NO lEDUCTION TYPE: PUMP Tank: Structurally Sound: EYES ❑ NO ®Type IV(50%reduction) Size of Pump Tank: 1500 Gallons Filter(s) Cleaned: ®YES ❑ NO ❑Type III(25%reduction) Pump Model: Goulds WE0511HHV Surface Water Diverted: ®YES ❑ NO ❑ None Pump HP: 1/2hp Scum Level: 10"2nd tank:0" Pump Voltage: 115V Head Settings. Sludge Level: 3"2nd Tank: 3" Pipework in good condition: ®YES El NO Scum plus Sludge level: 13"2nd tank: 3" ®2' ❑ 3' ❑other: Liquid Depth: 54" 2nd tank: Control floats operating: OYES ❑ NO Distribution Set @ inspection: TANK NEEDS PUMPING: OYES ® NO Effluent free&clear of solids: ®YES ❑ NO ®YES ❑NO 2nd TANK NEEDS PUMPING: EYES ® NO TANK NEEDS PUMPING: EYES ® NO Drain field: Effluent surfacing:OYES ®NO Notes and/or Corrective Action Needed: Traffic Protected:®YES ❑NO We performed the 2nd Type IV inspection for Repair Area Reserved: the year 2025. At the time of the inspection DISTRIBUTION TYPE: ®YES ❑NO Surface Water Diverted: the system was functioning as intended. We ®Manifold Elndividual valves ®YES ❑NO removed and cleaned the outlet filter. If you Line Cover Maintained: have any other questions please contact our ❑Serial/drop boxes ❑Distribution box ®YES ❑NO office. Thank you! LOW PRESSURE SYSTEM: Pump draw down: Turn-ups and/or Valves Located/ Gallons per cycle:266 Protected:®YES ❑NO Draw down length:8.8 Laterals Free of Excess solids:EVES El NO ,�, , Tether length if wide angle Laterals Flushed:®vEs ❑NO INSPECTOR SIGNATURE:(dA,;,79 float:4.75" (1/4- CY2) - /-()IS'r - 100- David Currier , ) Date of Inspection: Owner of: LAKE NORMAN 3/26/25 I rKE NORMAN SEWER AND SEPTIC PO BOX 889 ❑x Initial 06 Months ....sEwE it Denver, NC 28037 (704)-483-5125 N.. Field location_: License Number:995940 SEPTIC ®Onsite ❑ Offsite Subsurface Wastewater Inspection Form Offsite septic lot#: Name & Address of Owner: Tontrol panel: Jose Serrano TYPE OF SYSTEM_ 9408 Island Point Road Conduit sealed: EYES ❑ NO ❑Polystyrene Sherrills Ford, NC 28673 Alarm operating: ®YES ❑ NO ❑Chamber Panel location: ❑Panel 0 LPPBS SEPTIC TANK: ®Wall ❑Post 30"inches High ❑Gravel ❑LPP Size of Septic Tank: 1500+ 1000 Gallons Counter- Cycle: n/a Hour: n/a ❑Large diameter pipe Risers Readily Accessible: ®YES ❑ NO ❑Other: Signs of Infiltration: DYES ® NO _ tDUCTION TYPE: PUMP Tank Structurally Sound: ®YES ❑ NO ®Type IV(50%reduction) Size of Pump Tank: 1500 Gallons Filter(s) Cleaned: ®YES ❑ NO ❑Type III(25%reduction) Pump Model: Goulds WE0511HHV Surface Water Diverted: EYES ❑ NO ❑ None Pump HP: % hp Scum Level: 5" 2"d tank:0" Pump Voltage: 115V dead Settings Sludge Level: 13" 2nd Tank: 3" Pipework in good condition: EYES ❑NO Scum plus Sludge level: 18" 2nd tank: 3" 1E2' ❑ 3' ❑other: Liquid Depth:49" 2nd tank:49" Control floats operating: ®YES ❑ NO Distribution Set @ inspection: TANK NEEDS PUMPING: ®YES ❑ NO Effluent free&clear of solids: ®YES ❑ NO EYES ❑NO 2nd TANK NEEDS PUMPING: DYES E NO TANK NEEDS PUMPING: OYES ® NO Drain field: Effluent surfacing:❑YEs E NO Notes and/or Corrective Action Needed: Traffic Protected:EYES ❑NO At the time of the inspection the system Repair Area Reserved: functioning as intended. We DISTRIBUTION TYPE: EYES ❑NO was f g Surface Water Diverted: removed and cleaned the outlet filter ®Manifold ❑Individual valves EYES ❑NO Line Cover Maintained: We will be back in 6 months to perform ❑Serial/drop boxes ❑Distribution box OYES ❑NO the 2nd inspection. Thanks! LOW PRESSURE SYSTEM: Pump draw down: Turn-ups and/or Valves Located/ Gallons per cycle:266 ".— I Protected:EYES ❑NO Draw down length:8.8 / .2 4:,_ Laterals Free of Excess solids:EYES ❑NoTether length if wide angle INSPECTOR SIGNATURE.i J/� �� I Laterals Flushed:DYES ❑NO float:4.75"