Loading...
HomeMy WebLinkAboutBLD2007-02645 Lab no -128467-469 Cyl strength rpt.tif I Page: 1 of 1 ErA C~. O R I P R O P E R T Y 5 C I E N C E 5 281 Fairforest Way / Greenville, SC 29607 / 864-297-9944 / 864-297-0462 CYLINDER STRENGTH REPORT Job No: CH6051 Molded: 06/12108 Prepared: 06120/08 Lab No: 128467 Received: 06/13108 Date: 06120/08 Project: TARGET DISTRIBUTION CENTER Client: ARCHER WESTERN CONTRACTORS Contractor: FLORCON Technician: BILLY YOUNG Concrete Supplier: KERR Design Mix No: T54A467 Strength Requirement: 4000 PSI Tested @ (Days): 28 Location of Pour: Truck apron - Q line from 28.7 to 29.7 Truck No.: 15 No. of Specimens: 5 Slump: 5-314 inches Ticket No: 2450 Set No: 1 of 3 Air Content: 5.1 % Time Batched: 5:56 Quantity: 10/5!347 Unit Wt: 147.7 pcf Water Added on Job: 0 gals Time Molded: 6:20 Concrete Temp: 76 F Water Requested By: - Atmosphere Temp: 78 F Specimen Age Date Diameter Area Maximum Strength Type of Number (days) Tested (ins) (sq ins) Load oad (psi) Fracture Remarks 1 7 06/19/08 6.00 28.27 108350 3830 4 Comments. Tests conducted in general accordance with ASTM C 31, C 172, C 231, C 143, C 1064, C 39, and C 138 except initial curing conditions not documented. If you have any questions please call WEINHOLD, JOEL at 864-297-9944. REPORT DISTRIBUTION: TYPES OF FRACTURES ARCHER WESTERN CONTRACTORS \ MR. MICHAEL CARLIN (A-1) CARLISLE ASSOCIATES \ MR. EUGENE J. RESCH, P.E. (A-1) J \ t i , CLARY HOOD, INC \ MR. ANDY PAINTER (A-1) yi ItiI ~Ik ' 1 2 3 4 5 6 i Page: 1 of 1 E7m R o i P R O P E R T Y S C I E N C E S 281 Fairforest Way / Greenville, SC 29607 1864-297-9944 1864-297-0462 CYLINDER STRENGTH REPORT Molded: 06112!08 Prepared: 06/20108 Job No: CH6051 Date: 06120108 Lab No: 128468 Received: 06/13108 Project: TARGET DISTRIBUTION CENTER Client: ARCHER WESTERN CONTRACTORS Contractor: FLORCON Technician: BILLY YOUNG Concrete Supplier: KERR Design Mix No: T54A467 Strength Requirement: 4000 PSI Tested @ (Days): 28 Location of Pour: Truck aprons - Q line from 36.3 to 37.8 Truck No.: 15 No. of Specimens: 5 Slump: 6 inches Ticket No: 2464 Set No: 2 of 3 Air Content: 4.7 % Time Batched: 7:37 Quantity: 150/51347 Unit Wt: 147.5 pcf Water Added on Job: 0 gals Time Molded: 8:00 Concrete Temp: 80 F Water Requested By: - Atmosphere Temp: 79 F Specimen Age Date Diameter Area Maximum Strength Type of Remarks Number (days) Tested (ins) (sq ins) Load (Ibs) (psi) Fracture 1 7 06119/08 6.00 28.27 110376 3900 4 Comments: Tests conducted in general accordance with ASTM C 31, C 172, C 231, C 143, C 1064, C 39, and C 138 except initial curing conditions not documented. If you have any questions please call WEINHOLD, JOEL at 864-297-9944. REPORT DISTRIBUTION: TYPES OF FRACTURES ARCHER WESTERN CONTRACTORS \ MR. MICHAEL CARLIN (A-1) CARLISLE ASSOCIATES \ MR. EUGENE J. RESCH, P.E. (A-1) CLARY HOOD, INC 1 MR. ANDY PAINTER (A-1) r b~'1 v i t LL~i 1 2 3 4 5 6 Page: 1 of 1 E Q.0 R PROPERTY SCIENCES 281 Fairforest Way / Greenville, SC 29607 / 864-297-99441864-297-0462 CYLINDER STRENGTH REPORT Job No: CH6051 Molded: 06112108 Prepared: 06120/08 Lab No: 128469 Received: 06113108 Date: 06/20108 Project: TARGET DISTRIBUTION CENTER Client: ARCHER WESTERN CONTRACTORS Contractor: FLORCON Technician: BILLY YOUNG Concrete Supplier: KERR Design Mix No: T54A467 Strength Requirement: 4000 PSI Tested @ (Days): 28 Location of Pour: Truck aprons - Q line from 20.6 to 22.2 Truck No.: 611 No. of Specimens: 50 Slump: 5-314 inches Ticket No: 2479 Set No: 3 of 3 Air Content: 5.3 % Time Batched: 10:03 Quantity: 300/5/347 Unit Wt: 148.0 pcf Water Added on Job: 0 gals Time Molded: 10:30 Concrete Temp: 79 F Water Requested By: - Atmosphere Temp: 88 F Specimen Age Date Diameter Area Maximum Strength Type of s) ) Load (psi) Fracture Remarks Number (days) Tested (m (sq rns (lbs) 1 7 06/19/08 6.00 28.27 111252 3930 4 comments: Tests conducted in general accordance with ASTM C 31, C 172, C 231, C 143, C 1064, C 39, and C 138 except initial curing conditions not documented. If you have any questions please call WEINHOLD, JOEL at 864-297-9944. REPORT DISTRIBUTION: TYPES OF FRACTURES ARCHER WESTERN CONTRACTORS 1 MR. MICHAEL CARLIN (A-1) CARLISLE ASSOCIATES 1 MR. EUGENE J. RESCH, P.E. (A-1) , 4 l i ; r CLARY HOOD, INC 1 MR. ANDY PAINTER (A-1) 1 I + , I~1 Ski ' 1 f1 2 3 4 5 6