Loading...
HomeMy WebLinkAboutBLD2007-02645 Lab no -128060-062 Cyl strength rpt.tif I Page: 1 of 1 7M ORE P R OF E R T Y S C I E N C E S 281 Fairforest Way / Greenville, SC 29607 1864-297-9944 1 B64-297-0462 CYLINDER STRENGTH REPORT Job No: CH6051 Molded: 06/03108 Prepared: 06/11/08 Lab No: 128060 Received: 06/04108 Date: 07/08/08 Project: TARGET DISTRIBUTION CENTER Client: ARCHER WESTERN CONTRACTORS Contractor: FLORCON Technician: BILLY YOUNG Concrete Supplier. KERR Design Mix No: T54A467 Strength Requirement: 4000 PSI Tested @ (Days): 28 Location of Pour. Truck aprons - Q line from 23.9 to 25.5 Truck No.: 15 No. of Specimens: 5 Slump: 5-1/2 inches Ticket No: 2019 Set No: 1 of 3 Air Content: 4.8 % Time Batched: 4:14 Quantity: 10/51414 Unit Wt: 147.3 pcf Water Added on Job: 0 gals Time Molded: 5:00 Concrete Temp: 69 F Water Requested By: - Atmosphere Temp: 60 F Specimen Age Date Diameter Area Maximum Strength Type of Number (days) Tested (ins) (sq ins) Load (psi) Fracture Remarks (Ibs) 1 7 06/10/08 6.00 28.27 98388 3480 4 2 14 06/17/08 6.00 28.27 113911 4030 4 3 28 07/01/08 6.00 28.27 129973 4600 4 Comments: Tests conducted in general accordance with ASTM C 31, C 172, C 231, C 143, C 1064, C 39, and C 138 except initial curing conditions not documented. If you have any questions please call WEINHOLD, JOEL at 864-297-9944. REPORT DISTRIBUTION: ARCHER WESTERN CONTRACTORS 1 MR. MICHAEL CARLIN (A-1) TYPES OF FRACTURES CARLISLE ASSOCIATES 1 MR. EUGENE J. RESCH, P.E. (A-1) r 4i t i CLARY HOOD, INC 1 MR. ANDY PAINTER (A-1) J Iii ~ ~ i r Itil 5h ,J t 1 r 1 2 3 4 5 6 Page: 1 of 1 0RETM PROPERTY SCIENCES 281 Fairforest Way / Greenville, SC 29607 / 864-297-9944 / 864-297-0462 CYLINDER STRENGTH REPORT Job No: CH6051 Molded: 06103/08 Prepared: 06111/08 Lab No: 128061 Received: 06/04/08 Date: 07108/08 Project: TARGET DISTRIBUTION CENTER Client: ARCHER WESTERN CONTRACTORS Contractor: FLORCON Technician: BILLY YOUNG Concrete Supplier. KERR Design Mix No: T54A467 Strength Requirement: 4000 PSI Tested @ (Days): 28 Location of Pour: Truck apron - Q line from 29.7 to 31.2 Truck No.: 15 No. of Specimens: 5 Slump: 6 inches Ticket No: 2033 Set No: 2 of 3 Air Content: 5.2 % Time Batched: 6:29 Quantity: 150151414 Unit Wt: 146.9 pcf Water Added on Job: 0 gals Time Molded: 7:00 Concrete Temp: 71 F Water Requested By: - Atmosphere Temp: 64 F Specimen Age Date Diameter Area Maximum Strength Type of Remarks Number (days) Tested (ins) (sq ins) o ; (psi) Fracture 1 7 06110/08 6.00 28.27 98957 3500 4 2 14 06/17/08 6.00 28.27 109311 3870 4 3 28 07/01/08 6.00 28.27 126932 4490 4 C01T ments* Tests conducted in general accordance with ASTM C 31, C 172, C 231, C 143, C 1064, C 39, and C 138 except initial curing conditions not documented. If you have any questions please call WEINHOLD, JOEL at 864-297-9944. REPORT DISTRIBUTION: ARCHER WESTERN CONTRACTORS 1 MR. MICHAEL CARLIN (A-1) TYPES OF FRACTURES CARLISLE ASSOCIATES 1 MR. EUGENE J. RESCH, P.E. (A-1) CLARY HOOD, INC 1 MR. ANDY PAINTER (A-1) III tint 'J tl 1 2 3 4 5 6 Page: 1 of 1 0 R E` P R O P E R T Y S C I E N C ES 281 Fairforest Way / Greenville, SC 296071864-297-9944 / 864-297-0462 CYLINDER STRENGTH REPORT Job No: CH6051 Molded: 06103/08 Prepared: 06/11/08 Lab No: 128062 Received: 06104/08 Date: 07/08/08 Project: TARGET DISTRIBUTION CENTER Client: ARCHER WESTERN CONTRACTORS Contractor: FLORCON Technician: BILLY YOUNG Concrete Supplier: KERR Design Mix No: T54A467 Strength Requirement: 4000 PSI Tested @ (Days): 28 Location of Pour: Truck turn around second pour Truck No.: 18 No. of Specimens: 5 Slump: 6 inches Ticket No: 2051 Set No: 3 of 3 Air Content: 4.9 % Time Batched: 8:35 Quantity: 300/5/414 Unit Wt: 147.9 pcf Water Added on Job: 0 gals Time Molded: 9:00 Concrete Temp: 72 F Water Requested By: - Atmosphere Temp: 65 F Specimen Age Date Diameter Area Maximum Strength Type of Remarks Number (days) Tested (ins) (sq ins) Load (psi) Fracture 1 7 06110/08 6.00 28.27 101654 3600 4 2 14 06/17/08 6.00 28.27 111169 3930 4 3 28 07/01/08 6.00 28.27 115102 4070 4 Comments: Tests conducted in general accordance with ASTM C 31, C 172, C 231, C 143, C 1064, C 39, and C 138 except initial curing conditions not documented. If you have any questions please call WEINHOLD, JOEL at 864-297-9944. REPORT DISTRIBUTION: ARCHER WESTERN CONTRACTORS 1 MR. MICHAEL CARLIN (A-1) TYPES OF FRACTURES CARLISLE ASSOCIATES 1 MR. EUGENE J. RESCH, P.E. (A-1) i , r CLP.RY HOOD, INC 1 MR. ANDY PAINTER (A-1) LL~i 1 2 3 4 5 6