Customer Name: Sherrill Date of Inspection: 9/29/2022
Address: Sherrill-6944 Ingleside Drive Sherrill Ford,NC 28673 Arrival Time: 12:45:00 PM
System AX ID: AX-149567 Departure Time: 3:45:00 PM
County: Catawba
Permit No.
Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or D-BOX
sat fir`.. 1a i 11r 5 "@�gypp° pus-" '' @p N,A€1 ;..1t i
� � ! t , �� �;E K£x �.s�'ia9i,f. � .......,..: �<, a..< a '. -,�,U i.,W) -..
Tank At Site Tank 1
Tank 1 Inlet Readings Tank 2 Inlet Readings
0 Scum 2 Sludge Scum Sludge
Tank 1 Outlet Readings Tank 1 Outlet Readings
0 Scum 2 Sludge Scum Sludge
Clean Effluent Filler: Cleaned
Check for Influent or Effluent Blockages: No Blockage
Inspect Tank/Riser for Leaks: None Seen
Control Panel Inspection
Check Pump Operates In Manual Mode: Yes
Recirculation Pumps Recirculation Pump 1
Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters
0.8 Dose 10 Rest 9683 CT 131 ETM
Dose Pumps
Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters
Demand Dose Demand Rest 93 CT 503.1 ETM
Verify Conduit Seal: Added
. 11,.. AX-RT Treatment Pod lrfs' tfon
Inspect for Ponding or Bridging: None
Check and Record PSI: 4.5
Verify Orifice Position and Assess for Clogging: Cleaned
Check for Odors: None
Clean,Brush,Flush Lateral: Done
Recheck and Record PSI 4.5
Flush Pod Throroughly: Done
Inspect and Clean Vents: Cleaned
Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or DBOX
Recircul
ation Chamber inspection,.
Verify Inlet Flow: Inflow
Inspect Liquid: Normal Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
0 Scum 2 Sludge 0 Scum 2 Sludge
Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Replace Floats,See Notes
Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly
Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked
Verify No Leaking In Piping or Flex Hoses: Repaired,See Notes Verify Conduit Seal: Verified
Ultraviolet Disinfection Unit inspection
Does System Have a UV? Yes
How.Many UV Disinfectant Units Present? UV 1
After Disconnecting Power,Clean or Replace Bulb As Needed: Replaced
Flush Housing Thoroughly: Flushed
Return Power and Verify Proper Function: UV Repaired,See Notes
Dosing,Chamber inspection
Inspect for Tank/Riser Leakage: None Seen
Inspect Liquid: Normal Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
Scum Sludge 0 Scum 2 Sludge
Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly
Verily No Leaks In Piping or Flex Hoses: Repaired,See Notes Verify Neat Wrap of Float and Pump Cords. Checked
Inspect Pump Intake Cleaned Delivery Rate at Start Up: 19
Verify All Floats Wo'k Cperat:ng Properly Verify Conduit Seal: Added
LPP or P-Manifold or DBOX Inspection
Areas Mowed and Clear of Obstruction Yes Flush Laterals: Not a LPP
Area Free of Ponding or Surface Effluent: Yes Set and Record Head Pressure: N/A
Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly
Current Delivery Rate: 19.25 Pump Efficiency: 101
Return Valves and Control Panel 10 proper settings Done
Lantronics showing correct lights.Did not call in while onsite.Last
Control Panel Communication Checked: called in 9/16/22
inspection Notes
Dose splice box was full of water.Deed out box and found that it is
missing a plug.Put conduit seal to try to and keep water out until we can
return with a plug.Top cap of uv is cracked and needs replaced.Uv cord is
burnt needs replaced 50ft cord.Will have to return with replacement cord.
Connor Gavin
Operator Operators Signature
AQIWA
me clear leader.
AQWA Inc. -
Q1
2604 Willis Court,Wilson, NC 27896 V
Phone: 252-243-7693 — Email: aqwatammysanders@gmail.com
Customer Name: Sherrill Date of Inspection: 2/2212023
Address: Sherrill-6944 Ingleside Drive Sherrill Ford,NC 28673 Arrival Time: 1:15:00 PM
System AX ID: AX-149567 Departure Time: 2:45:00 PM
County: Catawba
Permit No.
Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or D-BOX
Septic Tank Inspection
Tank At Site Tank 1
lank 1 Inlet Readings Tank 2 Inlet Readings
1 Scum 15 Sludge Scum Sludge
Tank 1 Outlet Readings Tank 1 Outlet Readings
0 Scum 14 Sludge Scum Sludge
Tank inspection Questions Tank 1 Tank 2
Clean Effluent Filter: Cleaned
Check for Influent or Effluent Blockages: No Blockage
Inspect Tank/Riser for Leaks: None Seen
Control Panel Inspection
Check Pump Operates In Manual Made: Yes
Recirculation Pumps Recirculation Pump 1
Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters
0.8 Dose 10 Rest 29150 CT 393.5 ETM
Dose Pumps
Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters
Demand Dose Demand Rest 284 CT 515.5 FTM
Verify Conduit Seal: Verified
AX-RT Treatment Pod Inspection
Pod Inspection
.f.
Inspect for Ponding or Bridging: None
Check and Record PSI: 4.5
Verify Orifice Position and Assess for Clogging: Cleaned
Check for Odors: Foul Odor
Clean,Brush,Flush Lateral: Done
Recheck and Record PSI 4.5
Flush Pod Throroughly: Done
Inspect and Clean Vents: Cleaned
Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or DBOX
Recirculation Chamber Inspection
Verify Inlet Flow: No Inflow
Inspect Liquid: Normal Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
0 Scum 2 Sludge 0 Scum 3 Sludge
Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly
Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly
Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked
Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified
Ultraviolet Disinfection Unit Inspection
Does System Have a UV? Yes
How Many UV Disinfectant Units Present? UV 1
lb/Disinfectant Unit Inspection UV 1 •
After Disconnecting Power.Clean or Replace Bulb As Needed: Cleaned
Flush Housing Thoroughly: Flushed
Return Power and Verify Proper Function: Verified
Dosing Chamber Inspection _
Inspect for Tank/Riser Leakage: None Seen
Inspect Liquid: Normal Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
Scum Sludge 0 Scum 0 Sludge
Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly
Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked
Inspect Pump Intake: Cleaned Delivery Rate at Start Up: 19
Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified
LPP or P-Manifold or DBOX Inspection
Areas Mowed and Clear of Obstruction: Yes Flush Laterals: Not a LPP
Area Free of Ponding or Surface Effluent: Yes Set and Record Head Pressure: N/A
Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Property
Current Delivery Rate: 18.7 Pump Efficiency: 98
Retum Valves and Control Panel to proper settings Done
Control Panel Communication Checked: Panel called In.
Inspection Notes
Septic tank has high level of solids.Please schedule to have your septic
tank pumped at your convenience.8.5.4.4=37.4+2=18.7
Paul Smith
Operator Operators Signature
!AQWA 4 J1
The clear leader -D 9,5 s V
AQWA Inc.
2604 Willis Court,Wilson, NC 27896
Phone: 252-243-7693—Email: aqwatammysanders@gmail.com
Customer Name: Sherrill Date of Inspection: 8/16/2023
Address: Sherrill-6944 Ingleside Drive Sherrill Ford,NC 28673 Arrival Tme: 10:15:00 AM
System AX ID: AX-149567 Departure Time. 11:45:00 AM
County: Catawba
Permit No.
Inspection and Maintenance Checklist-AX-RT with I PP or P-Manifold or D-BOX
Septic Tank Inspection
Tank At Site Tank 1
Tank 1 Inlet Readings lank 2 Inlet Readings
1 Scum 6 Sludge Scum Sludge
Tank 1 Outlet Readings lank 1 Outlet Readings
0 Scum 4 Sludge Scum Sludge
.._. .. ... ..... ..,..iNr -,.._...e... . ...._. n�w,.v''+..il.r.Y...v�ldN.✓Mv l5Sr�4el�$ .W3J'a...:
Clean Effluent Filter: Cleaned
Check for Influent or Effluent Blockages: No Blockage
Inspect Tank/Riser for Leaks: None Seen
Control Panel Inspection
Check Pump Operates In Manual Mode: Yes
Recirculation Pumps Recirculation Pump 1
Pump 1 Tmer Settings Pump 1-Counters and Elapsed Time Meters
0.8 Dose 10 Rest 52526 CT 708.8 ETM
Dose Pumps
Pump 1 Tmer Settings Pump 1-Counters and Elapsed Tme Meters
Demand Dose Demand Rest 553 CT 532.2 ETM
Verify Conduit Seal: Verified
AX-RT Treatment Pod inspection
Inspect for Ponding or Bridging: None
Check and Record PSI: 4.5
Verify Orifice Position and Assess for Clogging: Cleaned
Check for Odors None
Clean,Brush,Flush Lateral. Done
Recheck and Record PSI 4.5
Flush Pod Throroughly: Done
Inspect and Clean Vents: Cleaned
Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or DBOX
Recirculation Chamber Inspection
Verify Inlet Flow No Inflow
Inspect Liquid Normal Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
0 Scum 0 Sludge 0 Scum 1 Sludge
Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly
Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Property
Pull Pump and Clean Screen: Cleaned Venfy Neat Wrap of Float and Pump Cords: Checked
Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified
Ultraviolet Disinfection Unit Inspection
Does System Have a UV? Yes
How Many UV Disinfectant Units Present? UV 1
After Disconnecting Power,Clean or Replace Bulb As Needed: Replaced
Flush HousIng Thoroughly: Flushed
Return Power and Verify Proper Function: Verified
Dosing Chamber Inspection
Inspect for Tank/Riser Leakage: None Seen
Inspect Liquid: Normal Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
Scum Sludge 0 Scum 0 Sludge
Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Property
Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked
Inspect Pump Intake: Cleaned Delivery Rate at Start Up: 19
Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified
LPP or P-Manifold or DBOX Inspection
Areas Mowed and Clear of Obstruction: Yes Flush Laterals: Not a LPP
Area Free of Ponding or Surface Effluent: Yes Set and Record Head Pressure: N/A
Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly
Current Delivery Rate: 18.4 Pump Efficiency: 98
Return Valves and Control Panel to proper settings Done
Control Panel Communication Checked: Panel called in.
Inspection Notes
39-47.5=8.5x4 x4=37.4+2=18.7
T—
Paul Smith
Operator Operators Signature
oJ4\
-03 IDS-0953730
AQWA
The clear leader.
AQWA Inc.
2604 Willis Court,Wilson,NC 27896
Phone:252-243-7693—Email:aqwatammysanders@gmail.com
Customer Name: Sherrill Date of Inspection: 10/29/2025
Address: Sherrill-6944 Ingleside Drive Sherrill Ford,NC 28673 Arrival Time: 2:38:00 PM
System AX ID: AX-149567 Departure Time: 4:26:00 PM
County: Catawba
Permit No.
Inspection and Maintenance Checklist-=AX-RT with LPP or P=Manifold or D-BOX
Septic Tank Inspection
Tank At Site Tank 1
Tank 1 Inlet Readings Tank 2 Inlet Readings
0 Scum 6 Sludge Scum Sludge
Tank 1 Outlet Readings Tank 1 Outlet Readings
0 Scum 6 Sludge Scum Sludge
Tank inspection Questions Tank 1, " Tank.2'
Clean Effluent Filter: Cleaned
Check for Influent or Effluent Blockages: No Blockage
Inspect Tank/Riser for Leaks: None Seen
Control Panel Inspection
Check Pump Operates In Manual Mode: Yes
Recirculation Pumps Recirculation Pump 1
Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters
0.8 Dose 10 Rest 59614 CT 2151.6 ETM
Dose Pumps
Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters
Demand Dose Demand Rest 1528 CT 596.7 ETM
Verify Conduit Seal: Verified
AX-RT Treatment Pod Inspection
Pod Inspection' p° 'Pod 1'
Inspect for Ponding or Bridging: None
Check and Record PSI:
Verify Orifice Position and Assess for Clogging: Cleaned
Check for Odors: None
Clean,Brush,Flush Lateral: Done
Recheck and Record PSI
Flush Pod Throroughly: Done
Inspect and Clean Vents: Vents Clear
Inspection and Maintenance Checklist-AX-RT with LPP or P-Manifold or DBOX
Recirculation Chamber Inspection
Verify Inlet Flow: No Inflow
Inspect Liquid: Normal Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
0 Scum 2 Sludge 0 Scum 1 Sludge
Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly
Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly
Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked
Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified
Ultraviolet Disinfection Unit Inspection
Does System Have a UV? Yes
How Many UV Disinfectant Units Present? UV 1
UV Disintectant Unitlnspection ; UV 1, _ UV2
After Disconnecting Power,Clean or Replace Bulb As Needed: Cleaned
Flush Housing Thoroughly: Flushed
Return Power and Verify Proper Function:, Verified
Dosing Chamber Inspection
Inspect for Tank/Riser Leakage: None Seen Turbidity Reading: 0.00
Inspect Liquid: Normal Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
Scum Sludge 0 Scum 1 Sludge
Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly
Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked
Inspect Pump Intake: Ok Delivery Rate at Start Up: 19
Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified
LPP or P-Manifold or DBOX Inspection
Areas Mowed and Clear of Obstruction: Yes Flush Laterals: Not a LPP
Area Free of Ponding or Surface Effluent: Yes Set and Record Head Pressure: N/A
Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly
Current Delivery Rate: 18.7 Pump Efficiency: 98
Return Valves and Control Panel to proper settings Done
Control Panel Communication Checked: Panel called In
Inspection Notes
41-49.50=8.5x4.4=37.4+2=18.7+19=98%Tested internet connection with tablet
and ethernet adapter.Had to cycle power to get panel to call in.
Blake Efird
Operator Operators Signature