HomeMy WebLinkAboutCBPR-1-10-3683 mackie johnson arch plan review comments.tif i L bip 10--~bs3 MACKIE JOHNSON, ARCHITECT j OFFICE: 828-464-1028 FAx: 828-465-4562 MAILING ADDRESS SHIPPING ADDRESS P. 0. Box 428 11 4T" AVENUES W CONOVER, N. C. 28613 ONOVER, N. C. 28613 MJA@MACKIEJOHNSON.COM FEBRUARY 18, 2009 PROJECT CONSTRUCTION MEMO (PLAN REVIEW COMMENTS) NUMBER (RESPONSE TO CODE COMMENTS DATED 01-29-10) DELIVERY: HAND DELIVERY - ONLY PROJECT: INTERIOR ALTERATIONS FOR: CHILD DEVELOPMENT SERVICES ASSOCIATION 1985 S.E. TATE BLVD. HICKORY, NORTH CAROLINA CONTRACTOR: DAVID E. LOOPER & COMPANY, INC. FROM: BARRY (CARD, AIA - MACKIE JOHNSON, ARCHITECT TO: CATAWBA COUNTY- CLARA COULBOURNE HICKORY DEVELOPMENT ASSISTANT CENTER COPY TO: DAVID E. LOOPER & COMPANY, INC. REFERENCE: REPLY TO REVIEW COMMENTS DATED 01-29-10 PLANNING AND ZONING COMMENTS: (N/A) ENGINEERING STATUS: (N/A) BUILDING STATUS: (DISAPPROVED) COMMENT #1: SHEETS A1.0: PROVIDE DETAILED CONSTRUCTION COST TO SHOW 20% DISPROPORTIONALITY COST AND HOW IT IS BEING SPENT PER NCBC 3409.7(1) (SEE REVISED DRAWING A1.0, A3.0 AND ATTACHED INFORMATION FROM DAVID E. LOOPER, INC. FOR COMPLIANCE) COMMENT #2: SHEETS E-2: MOVE EXIT SIGNS AT DOOR A402 TO DOOR A400 (EXIT THRU WAITING AREA) TO PREVENT MERGING OF EXITS FROM CONFERENCE ROOM. (SEE REVISED ELECTRICAL DRAWINGS FOR COMPLIANCE) PAGE 1 OF 2 F c- 10-3683 COMMENT #3: GENERAL NOTE: THE FIRE DAMPERS SHOWN ALONG CORRIDOR A414 ARE NOT REQUIRED BY THE BUILDING CODE AS THE CORRIDOR IS NOT A RATED CORRIDOR PER NCBC. TABLE 1017.1 FOOTNOTE "F". (SEE REVISED MECHANICAL DRAWINGS FIRE STATUS: (PLAN RECEIVED-APPROVED WITH NOTES COMMENT #1: THE RATED DOOR WILL NOT BE REMOVED SEPARATING CORRIDOR A414 AND A407. FIRE DOOR SHALL BE LABELED ACCORDING TO THEIR INTENDED USE. COMMENT #2: WILL VERIFY ALL DOORS IN RATED WALLS ARE PROVIDING OR MAINTAINING PROPER OPENING PROTECTIONS. COMMENT #2: THE DIRECTION OF EXIT SIGN IN CORRIDOR A402 WILL BE RELOCATED SUCH THAT IT WOULD DIRECT OCCUPANTS THROUGH WAITING AREA A400.. ATTACHMENTS: FOUR SETS OF REVISED DRAWINGS ONLY. PAGE 2OF2 END OF RESPONSE TO CODE COMMENTS DATED 01-29-10 C6P#,-1-10 3683 CDSA 20% Disproportional ity Cost Breakdown Total Contract Before Disproportionality $66,245.00 20% Disproportionality Cost $13,249.00 Men's Gang Bathroom Upgrades General Conditions $1,024.00 Patch Ceramic Tile $375.00 Patch Plaster Ceilings $1,000.00 Add New Toilet Partition $1,470.00 Remove One Toilet, Add One New ADA Sink $3,985.00 Total $7,854.00 Add New Bi-level Water Cooler General Conditions $608.00 Demo Existing and Add new Backer Board $1,200.00 Material and Labor New Bi-level Water Cooler $2,853.00 Total $4,661.00 Add New Handicap Sign Parking Spaces General Condition $135.00 Labor and Material to add Signage $900.00 Total $1,035.00 Total for Both Changes $13,550.00 i 5