HomeMy WebLinkAboutBLDR-12-09-3006 Engr ltr on truss shortening 12-7-09.tif TAYLOR AND VIOLA STRUCTURAL ENGINEERS J. KIRK VIO1,A, P.E. JAMES S. TATE. P.E. J,,ksow M. ReLP. P.E. December 7. 2009 ( s a ' Mr. Scott Miller Hiller Home Builders 4010 11t1i Street NE Hickory, NC 28601 t 1 r RE: Mitchell Residence 1 I 496 1"1°i Avenue Drive NE Hickory. North Carolina I Dear Scott: a At your request, we visited the above referenced residence to obser\e two existing wood floor ' trusses that need to be shortened to allow for a new stair to be installed. 'File floor trusses in question are 12" deep and span about 18'-8". The new truss length needs to be about 1 1'-10" ~ long to allow for the new stair. 4 VAre recommend shortening cacti truss to allow for a bottom chord panel point on each truss to , align with the supporting wall below. .Also, each truss should be reinforced on each side with 3/" plywood extending back about 8'-0" from the new bearing end. The plywood should be nailed and glued to the sides of each truss. . if ti.ou have any questions or need further assistance, please call us. i Sincerely. 3 TAYLOR & VIOLA STRUCTURAL ENGINEERS, P.C. J. Kirk Viola, P.E. LP f k P.O. Box 2616 • 308 15T" STRLLT SE . HICKORY. NOR'III CAROLIN 28603 Tt:LFPUONF: (828) 328-6331. FAX: (828) 322-1 801