HomeMy WebLinkAboutSAFE-11-09-2911 Engr ltr on bearing wall 2-4-10.tif CAMPBELL D E S I G N D ECE~VE FEB - 4 2010 Hickory City Hall BUILDING SERVICES DIVISION 76 N. Center St. CATAWBA COUNTY Hickory, NC 28601 PERMIT CENTER Brandon Lewis, Lead Plan Review Official 828.466.5130 press 01 BLewis@catawbacountync.gov REF - determine bearing wall per site visit for newly created cased opening -per building inspections and fire inspections request -per space belonging to Dean Powell at highland park Brandon Lewis, I made a site visit t look at conditions around the newly created opening. There is a steel roof beam (W shape or "I" beam)that caries steel bar joist loads and transfers that load to steel columns and to footings. This load path from roof down does not transfer any loads to interior walls so the wall is non-load bearing. F The wall is a light gage metal stud wall with studs at approx. 24" on center with 5/8" gyp board each side. Call me if you have any questions Regards, Ray Campbell, AIA Architect Campbell Design PA Architecture and Interior Design 4511-B North Highway 16 Suite B Denver, NC 28037 Z ' 704-489-1438 Fax: 704-489-1439 Mobile: 828-312-6614 4511 North Highway 16 Suite B Denver, NC 28037 • (704) 489-1438 • Fax (704) 489-1439 • campbelldesign.info - ~1- oa~Z,°t l1 5pOr, jE MEN; CAMPBELL D E S I G N D EC EP W E FEB - 4 2010 Hickory City Hall BUILDING SERVICES DIVISION 76 N. Center St. CATAWBA COUNTY Hickory, NC 28601 PERMIT CENTER Brandon Lewis, Lead Plan Review official 828.466.5130 press 01 BLewis@catawbacountync.gov REF - determine bearing wall per site visit for newly created cased opening -per building inspections and fire inspections request -per space belonging to Dean Powell at highland park Brandon Lewis, I made a site visit t look at conditions around the newly created opening. There is a steel roof beam (W shape or "I" beam)that caries steel bar joist loads and transfers that load to steel columns and to footings. This load path from roof down does not transfer any loads to interior walls so the wall is non-load bearing. The wall is a light gage metal stud wall with studs at approx. 24" on center with 5/8" gyp board each side. Call me if you have any questions Regards, Ray Campbell, AIA Architect Campbell Design PA Architecture and Interior Design anon* 4511-B North Highway 16 Suite B Denver, NC 28037 704-489-1438 Fax: 704-489-1439 Mobile: 828-312-6614 4511 North Highway 16 • Suite B • Denver, NC 28037 (704) 489-1438 • Fax (704) 489-1439 . campbelldesign.info