Loading...
HomeMy WebLinkAboutIMPV-2-10-4516.TIF CDP Nile Number 36422 County ID Number: EHPR-10-o9-2218 *Site Modifications ❑ Open Fill Sheet No grading or construction activity is allowed in areas designated for system and repair without approval of Health Department. Entire septic area and septic repair area must be "fenced off" for protection. No building materials are permitted to be stored or placed on the septic area/repair area. Do not drive, grade, cut, or fill over septic area or septic repair area. *Permit Conditions The issuance of this permit by the Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. See all other requirements on engineered plans by Piedmont Design, dated December 28, 2009. See soil notes in report submitted by SBME , dated December 15. 2009. The Improvement Permit shall be valid for 5 years from date of issue with a site plan (means a drawing not necessarily drawn to Site Plan scale that shows the existing and proposed property lines with dimensions, the location of the facility and appurtenances, the 5) site for the proposed Wastewater system, and the location of water supplies and surfacewaters). Plat The Improvement Permit shall be valid without expiration with plat (means a property surveyed prepared by a registered land O surveyor, drawn to a scale of one inch equals no more than 60 feet, that Includes: the specific location of the proposed facility and appurtenances, the site for the proposed Wastewater system, and the location of water supplies and surface waters. Plat also means, for subdivision lots approved by the local planning authority and recorded with the county register of deeds, a copy of the recorded subdlvisions plat that is accompanied by a site plan that is drawn to scale). The Department and Local Health Department may Impose conditions on the issuanceand may revoke the permits for failure of the system to satisfy the conditions, the rules, or this article. This permit is subject to revocation if the site plan, plat, or intended use changes (NCGS 130A-335(f)). The person owning or controlling the system shall be responsible for assuring compliance with the laws, rules, and permit conditions regarding system location, installation, operation, maintenance; monitoring, reporting, and repair (.1938(b)~ Applicant/Legal Reps. Signature Requi Oyes ONO Applicant/Legal Reps. Signature Date: 3 2246 - Me en McBride Issued By: 9 Date of Issue: 0 a / 0 5 / a 0 1 0 Authorized State Agent: OValid without Expiration? BHand Drawing Olmport Drawing **Site Plan/Drawing attached.**- Total Time:(HH:MM) 0 0 Hours 0 0 Minutes Page 2 of 3 Additional Permit Conditions for the Improvement Permit And Authorization to Construct the Wastewater System Walter Conine Residence - 8772 Popular Ln. Sherrills Ford, NC Catawba County Case #EHPR-10-09-2218 1. This system is designed to serve a 2-bedroom single family residence only with a daily design flow of 240 gallons per day. All construction and system component installation shall be in accordance with plans approved by NCDENR, DEH on January 26, 2010 prepared by Piedmont Design Associates, PA, dated December 28, 2009, and referenced as attached. 2. The septic system contractor shall be required to lay out the entire system and schedule a pre-construction conference with a representative of Catawba County Environmental Health on site prior to initiating construction of the system. Installation Contractor shall be certified at a minimum Level 4. 3. All prefabricated concrete pump tanks shall be leak tested and approved prior to installation of pump system components. Pre-approved and specified plastic tanks are exempt from this requirement. 4. All components of the system shall be installed in accordance with design engineer and manufacturer's specifications and shall be demonstrated as properly functioning prior to approval. 5. The design engineer shall be present at construction as sufficient to verify that the installation has been completed in accordance with all plans and design specifications. 6. A complete set of "as built" diagrams, certified by the design engineer, shall be submitted to Catawba County Environmental Health upon completion of installation and prior to final approvals. 7. Final landscaping of the nitrification fields shall be performed by placement of approved soil cover over the entire field, slightly mounded in the center, and gently sloped to the sides to shed surface water from the field. Seed and straw shall be applied to the finished surface and appropriately maintained. 8. Pressure head at headworks shall be maintained as per drip system manufacturer's specifications. 9. The system is categorized as a Type V. A contract with a certified subsurface system operator, signed by all required parties shall be submitted to Catawba County Environmental Health upon completion of installation and prior to final approvals. Required ORC inspection frequency is twice yearly. r' K2)