Loading...
HomeMy WebLinkAboutBLD2009-01233 Engr Dwg - field report.tif PROJECT PAGE OF REFERS r PROJECT NO. CLIENT I ~ • ~ ST E WA R T ( DESIGNER °ATE CHECKER DATE f 1 3 i 1 - I - E t + i - - ~ 6 , i I 1 I - i 1 1 ~ I I { 1 ~ _ 1 00 { r- - i IL i I , i• i ` y i i I + ! - r l -38 f f 1 ENGINEERIfNG.INNOVATION SOLUTIONS. i?c:;<an c„r T Cr,MP,0IIF vC T %u .33e ;r ::.liiF 282112 F 334 'n `s Y Co 0 0 L :x N N N N ■ ■ w C ~ N Q N O U o O W C) O tI N ■ O~ C r O U C) C) 6 r N 7 W N o O 11 r Y 1 ® W W W i ® mi a Z a a j = v> o w m Q ° A o~ oa m G. 'u m a~ O O ~ L L L L L 0 0 ®oco go 000 _ r c M5' c~ c s O a•o -o° :o na a®x.~ o~ 30° o O a O O - 03 0 a C A ` °o '0 C W N U. O N r ~ 'd O 7 u a. ~ 01 u o o c A 0 co Q Q Q LL Z Z Z M tm V c Z O ° A CL ~ E co w E N U) (n o 0 C V oU > st v Cn V o n 0 x x x 3 3 v a t W x d x x x N ~ U E r N N N li O = O x CO CO 3 ~ c U o 0 0 j U cm i: x x x 0 Fo v ~ A N cV (V O o a l U IN IN c c ce 4F 0 ~ rn y o o m e t0 Z{ O vO - .-1 0 1~0 m z - C ® O 0 Q O O o .a -0 E "4 12/01/2009 17:24 8286954491 ECS CON n 2 Iv4 At, PAGE 01 ~f r j to r `fi r ECS CatreMas, L Geoteeheienl - CowbueNoa Materials + taviroamentid ~O! ! iCagarHo~dcva Ciramsbpw, NA CafMM XM7 . Sottdubmg 336456-7152 / Fax 336456-1039 H~YD 1~_GGR RECORD C -v-^t•f FCS P'rajecr No. ECS Project X== Date t,l- , ?E.YrmOmETER SLOW CG! ti'T5 . I.OCA?tOiYISO(LiJESRG'"f[ON I DI:Pir i 1-3/-1" 1.3/4" l•;;s. ! Ft E,L~, ~2sr! C ~XtS-i"!n9 ~ ~ ~ ~ ~ ~ es e: ex►571z~ ~ ri S C LA 5 As-Xk y t~ 17 1 1 r 5 ar C-► SD SL i -"L I to 1t 1 R~~ Ctpy. so - tS,dstS~rn Stiff 6ss.~1~t1 Iu' tl i t' y t~ It7 t( trr+A CCA fl% UU !J•E~ L • ~G~Lv~~- aIL7J -TM ICS Carolinas. LLP 4811 Koger Boulevard Greensboro, NC 27407 (336) 856-7150 FIELD REPORT (336) 856-7160 Project No. 09:17995 Report No. 5 Project CVCC Student Services Building Day & Date Tuesday 12/01/2009 Location Hickory, NC Weather 500/ Sunny On-Site Time 1.00 Client Catawba Valley Community College - Mary Sherrill Contractor Montgomery Development - John Petrick Lab Time 0.00 Travel Time* 0.50 Total 1.50 ` Remarks Footings/Test Pits Re Obs.Time 0.00 Trip Charges* Tolis/Parking* Mileage* 15 Time of Arrival Departure Chargeable Items 02:30P 03:30P • Travel time and mileage will be billed in accordance with the contract. Summary of Sewkm Performed (field test data, (OCi~pnR, drvaan is t , IN S am esdoons) i Murals Conbeftd The undersigned arrived on site, as requested, to observe the excavation of footings: footing 1 at rotunda, footing 4 at rotunda, and footing along existing footing B-6. Also observed test pits along existing CMU wall. I was asked to perform DCP and soils in the first two test pits. The other two were too deep for access.Perform Hand Augers and DCP. See attached sheet. Utilizing a Dynamic Cone Penetrometer (ASTM STP-399) to check the bearing capacity of soil at the aforementioned footing locations, test results indicated that soils, at the areas and elevations tested, were capable of supporting a foundation designed for a net allowable bearing capacity of 2500 psf after the two at the rotunda were to be undercut 12 inches and replaced with concrete. the soils were wet and soft down 12 inches. The contractor agreed. The areas measured 2x(4'x2'xl')= 0.59 cubic yards. By Alan L. Raulsten, - CMT Project Manager 1400 216040 ECS Carolinas. LLP 48112oger Boulevard Greensboro, NC 27407 (336) 256-7'50 LETTER OF TRANSMITTAL (336) 256-7160 CAROUNIeAs r December 2, 2009 RE: CVCC Student Services Building Catawba Valley Community College ]ECSCS Job # 09:17995 2550 Highway 70 SE Hickory, NC 28602 Pests: Location: 2550 US Highway 70 SE ATTN: Ms Mary Sherrill Hickory, NC We are enclosing: X Materials Engineering Division Reports X For your use X As requested CC: Catawba Valley Community Calkge - Allen Kirby Montgomery Development - John Petrick Montgomery Development Carolina Corp. - John Fugo ADW Architects - John Kappers Stewart Engineering - L Williams ENCL: Field Report # 5 12/01/2009 Footings/Test Pits .1 f J H ' L. Ra ston t~ Br Manager CMT Project Manager