HomeMy WebLinkAboutAUTH-08-2016-076128.TIF �01, CATAWBA COUNTY Case#
.±iiink L Public Health Department Subdivision
; , Environmental Health Division PIN# 460701274619
'.i. }-Pb Bos 389, 100-A Southwest Blvd,Newton.NC 28658 LOT# 1
/842_NAME ON PERMIT: *SPIVEY CONSTRUCTION, PO BOX 4268, MOORESVILLE NC 28117
Site Address: 3579 DOCKSIDE LN, SHERRILLS FORD NC 28673
Property Size: Square Feet:60,112.80 Acres:1.38
Directions: Hwy 165 to Hwy 150E Left on Mt.Pleasant Rd. corner of Mt. Pleasant and dockside lane
Owner/Authorized Representative Acknowledgement of Permit Receipt
I certify that I am the owner or authorized agent(owner's authorization required) representing the owner of the
property described above.
0,1 As the property owner or authorized representative, I have received the above referenced permit(s) as
requested in the application for service RBPR-07-2016-24385 by the following method(s):
-Received in Person
Facsimile Transmittal (Return form with signature required)
,\11 Electronic Image Transmittal/ E-mail (Return receipt required)
y. 1h'N" As the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the North
Carolina Laws and Rules for Sewage Treatment and Disposal Systems (15A NCAC 18A .1900), and/or
Well Construction Standards (15A NCAC 2C .0100), shall apply to the issuance of this permit and the
construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 08/25/2016
2 `
Owner/Authorized Representative Signature (.}�
Date � --Ia - it,
Documentation of Permit(s) Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of person sending permit)
Signature Date/Time
Method: Fax Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We want to hear from you. Please take a few moments to complete our customer service survey at:
http://www.surveymonkey.com/s/EHCustomerservice
ehprnnil 08/25/2016 10:26
` ,A CATAWBA COUNTY �B .r :'S�e Case# AUTI-I-08-2016-076128
.F' L Public Health Department i•' •',•• st - Subdivision
Q Environmental Health Division di I.'• • - ••• , PIN# 460701274619
`""� ly PO Box 389, 100-A Southwest Blvd, Newton,NC 28658 IIS,,� G • LOT# 1
Jt;42 sM yr.'t• 1.
a.14a or- ..lo
Orr- •
NAME ON PERMIT: *SPIVEY CONSTRUCTION, PO BOX 4268, MOORESVILLE NC 28117
Site Address: 3579 DOCKSIDE LN, SHERRILLS FORD NC 28673
Property Size: Square Feet:60,112.80 Acres:1.38
Directions: Hwy 165 to Hwy 150E Left on Mt.Pleasant Rd. corner of Mt. Pleasant and dockside lane
Authorization to Construct Permit
Authorization to Construct Wastewater System (Required for Building Permitl
* See site plan and number of additional attachments ( ).
Proposed Wastewater System: 25% REDUCTION Wastewater Flow 360 g.p.d
Type: IIIG - OTHER NON-CONN TRENCH SYSTEMS
Soil LTAR: .3 g.p.d./ft2
Permit Category: New Septic
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 3
Wastewater System Requirements
Tank Size: New Tank 1,000 gal Pump Tank gal Grease Trap gal
Dosing Volume gal Pump Specs:_ GPM @ TDH
Pressure Head • ft Draw Down in
Drainfield: Total Area: 900 sq ft Total Length: 300 ft Maximum Trench Depth 36 in
Aggregate Depth in Trench Width 9 ft
Minimum Soil Cover 12 in Minimum Trench Separation 9 ft on center
Number of Drain Lines 4
Distribution: Serial
Pre Treatment: NONE
Additional Specifications: Proposal submitted by Gary McNeeley with Michael Athanas and Associates LSS. Keep all parts
of septic system and any future repair minimum: 100' from any well, 10' from property lines, 10' from
home. Lines to be installed on contour. Do not grade drive or fill over system or repair area or
permits will be revoked. Outlet plumbing from home must be placed in specified location or a pump
may be required. Well is on adjacent property to be shared.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
»»> DO NOT INSTALL SYSTEM UNDER WET CONDITIONS ««<
Proposed Repair
Repair System Required? Required System Class: IVA Proposed System: 50% REDUCTION
Distribution Type:: LPP Soil LTAR: _3 g.p.d./ft2
PUMP REQUIRED ***** OPERATOR REQUIRED
ehperm it 08/25/2016 10:27
�g '� CATAWBA COUNTY Case# AUTH-08-2016-076128
rsaPublic Health Department Subdivision
Gv Environmental Health Division PIM460701274619
'll
Lo< PO Box 389, 100-A Southwest Blvd, Newton.NC 28658 LOT# 1
/842 :.
NAME ON PERMIT: *SPIVEY CONSTRUCTION, PO BOX 4268, MOORESVILLE NC 28117
Site Address: 3579 DOCKSIDE LN, SHERRILLS FORD NC 28673
Property Size: Square Feet:60,112.80 Acres:1.38
Directions: Hwy 165 to Hwy 150E Left on Mt.Pleasant Rd. corner of Mt. Pleasant and dockside lane
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of
the applicanUproperty owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met.
This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site
conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit
was issued in compliance with the provisions of the North Carolina 'Laws and Rules for Sewaee Treatment and Disposal Systems' (15A
NCAC 18A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will
continutto function satisfactorily for any given period of time.
Jason Boyd 08/25/2016
AUTHORIZED STATE AGENT APPROVAL DATE
Permit Expiration Date: 08/25/2021
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehpennit 08/25/2016 10:27
/ iii-
y : .
! v
/CO
/itt
ii ' ,
6e.�§ 27 S) / orf
/
k /
o / •
)
/®
/ • \ 7 ®
t- z
/ ; O
m \ O `&
/ \ Ism
/ \ , • `
2 Q,- _
\ / ~ 1 ^ » .
ILI ±
\ / " . . . \ .
9.3 1 / , .
/ \ \ - /
.0 \ § y %
),I Ur)
) � ` j 11,
j ^ 7ta .
. ) m
\ , ,
C7 . i�
¥ 0
cc \ .
\ & � ,
. §/ '
ƒ ,. w� .
\ \ •
0 / •
0 ill'o
\ Se; '
.IS.A.•
rJ:k p
ea-
la „sr
`:. .aah; ^
MICHAEL ATHANAS &ASSOCIATES
LICENSED SOIL SCIENTIST
561 Ennis Rd.
Wcddington, NC_8173
(704)576-3887
Reference: Data Sheet for 3579 Dockside Ln. Sherrils Ford
House Footprint: 50' x 50'
Building Setbacks: 30' front/rear, 15' side
Water Source: Private well
Number of Bedrooms: 3/360 GPD
Proposed LIAR: 0.3 GPD/FT2
Proposed System Type: 25% Reduction
Proposed Repair System Type: PPBPS
Distribution: Gravity-End cap/Drop boxes
Septic Tank Size: 1000 gallons
Proposed Trench Bottom: 36”
Line Design Length Actual Length
Pink 1 55'
White 2 65'
Blue 3 80'
Pink 4 75' 75'
White 5 75' 75'
Blue 6 75' 75'
Pink 7 75' 75'
Initial System: 300' Repair System: 200'
Comments:
DEPARTMENT OF HEALTH AND HUMAN SERVICES Sheer _!
_I of
DIVISION OF PUBLIC HEALTH, ENVIRONMENTAL HEALTH SECTION PROPERTY ID/i:-60701274619_
ON-SITE WATER PROTECTION BRANCH COUN Yi Catav:ha_
SOIL/SITE EVALUATION
Jor ON-SITE WASTEWATER SYSTEM
(Complete all fields in lull)
OWNER: Dockside Storage LLC APPLICATION DATE
ADDRESS: DATE EVALUATED:
PROPOSED FACILITY: 3 hdrm PROPOSED DESIGN FLOP'(.1919): 360 GPO PROPERTY SIZE:_1.38 AC
LOCATION OF SITE:3579 Dockside Ln,Sherrils Ford PROPERTY RECORDED:
WATER SUPPLY: ? Private ❑Public E. Well ❑ Spring 0 Other
EVALUATION METHOD: Auger Boring E Pit ❑Cut TYPE OF WASTEWATER: E Sewage ❑Industrial Process ❑Mixed
• - r ••
P
SOIL.MORPHOLOGYR
I OTHER
F . I. - (.1941) ;PROFILE FACTORS -'
1 .L .t940 :+� al I
1;1NDSCAPI IIORIY,ON •
; -- , . . _ '
POSITION! DEPTH - .1942 PROFILE .•
S SLOPE,' (h\;j't• ,1941 .1941 r. SOIL. 1943 .1'956, , .1944 .!:i•' CLASS
: STRUCl11R1!": COPS1'7INCE/ WETNESS/ ,SS/ , i' SOIL SAPRO ' RESIR ,:& LIAR
. TF\FUR}I i \II\I RALOGI" COLOR 1 ,E '`DEPTH CI ASS • 1101212 , „ _. •
•
LS 6% 0-30 k CL WSBK FR SS SP SCXI' N/A 30' P-C SAP I N/A PS 0.3-0.4
PIT 30-61 SI.SAP M VER SS SP SEXY
) PS '
1
LS 6% 0-18 R C SBK FR SS 51'SEXP N/A 34:' 8IA PS 0.3-0.4
"— r-C SAP
PIT !8-t0 R CL WSBK FR 5S SP SEXP 1,S
2 40-62 SL SAP M VER SS SP SEXP
1 I
LS 6% 0.18 R C SBK FR SS SP SEXP N/A 32 N/A PS 0.3-0.4
PIT IR-32 R CL IVSRK PR SS SP SEM'
F-csAP I
3 32-65 SI.SAP M VFR SS SP SEXY PS
,
DESCRIPTION INITIAL SYSTEM REPAIR SYSTEM OTHER FACTORS (.1946):
SITE CLASSIFICATION(.1948): I'S
Available Space(.1915) 900 FT2 400 FT2
SystemT e(s 25% EVALUATED BY: MASA
S
>p ) Reduction 1'PBPS OTHER(S) PRESENT: -
Site LIAR 0.3 0.3
COMMENTS'.
Updated Feb: ")2014