HomeMy WebLinkAboutAUTH-07-2016-075126.TIF ^y, CATAWBA COUNTY Case# _
,TLitinti Public Health Department Subdivision PHIL CLINE PROP
< : ;.111/ � I Environmental Health Division P1N# 362908884622
-fr PO Box 389. 100-A Southwest Blvd,Newton. NC 28658 LOP/ 59-62 & 94-97
1.42 su
NAME ON PERMIT: CHRISTOPHER FRYE, 2153 DOVE ST,
Site Address: 2153 DOVE ST, NEWTON NC 28658
Property Size: Square Feet: 30,056.40 Acres:0.69
Directions: East Hwy 10, turn right on dove st house on the left.
Owner/Authorized Representative Acknowledgement of Permit Receipt
0 I certify that I am the owner or authorized agent(owner's authorization required) representing the owner of the
property described above.
613 As the property owner or authorized representative, I have received the above referenced permit(s) as
requested in the application for service RBPR-06-2016-24177 by the following method(s):
\/ Received in Person
Facsimile Transmittal (Return form with signature required)
Electronic Image Transmittal/E-mail (Return receipt required)
aAs the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the North
Carolina Laws and Rules for Sewage Treatment and Disposal Systems (15A NCAC 18A .1900), and/or
Well Construction Standards (15A NCAC 2C .0100), shall apply to the issuance of this permit and the
construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 07/29/2016 0 �.
Owner/Authorized Representative Signature At
Date 7 -z i f ) b I
Documentation of Permit(s) Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of person sending permit)
Signature Date/Time
Method: Fax Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We want to hear from you. Please take a few moments to complete our customer service survey at:
http://www.surveymonkey.com/s/EHCustomerService
(Alper mit 07/29/2016 12:19
CATAWVBACOUNTY Err: . r .ga Case# AUTI-1-07-2016-075126
•
AIL;
.Z' ; Public Health Department S• r "1. Subdivision PHIL CLINE PROP
4 , `''6741
p i1 "- Environmental Health Division I �� PIN# 362908884622
z't,. PO Box 389. 100-A Southwest Blvd, Newton, NC 28658 ' . 1. LOT# 59-62 & 94-97
4342
al.
NAME ON PERMIT: CHRISTOPHER FRYE, 2153 DOVE ST,
Site Address: 2153 DOVE ST, NEWTON NC 28658
Property Size: Square Feet:30,056.40 Acres:0.69
Directions: East Hwy 10, turn right on dove st house on the left.
Authorization to Construct Permit
Authorization to Construct Wastewater System (Required for Building Permit)
* See site plan and number ojadditional attachments ( ).
Proposed Wastewater System: 25% REDUCTION Wastewater Flow 360 g.p.d
Type: IIIB - SYSTEM W/SINGLE EFFLUENT PUMP
Soil LIAR: 0.35 g.p.d./ft2
Permit Category: Expansion
Type of Facility: Primary Residence -
Basement? No Basement Plumbing? No Bedrooms: 3
Wastewater System Requirements
Tank Size: Existing Tank Unknown Size Pump Tank 1,000 gal Grease Trap gal
Dosing Volume 119 gal Pump Specs: 21.33 GPM @ 11 TDH
Pressure Head 2 ft Draw Down 5.7 in
Drainfield: Total Area: 480 sq ft Total Length: 160 ft Maximum Trench Depth 36 in
Aggregate Depth in Trench Width 3 ft
Minimum Soil Cover 12 in Minimum Trench Separation 9 ft on center
Number of Drain Lines 2
Distribution: Pressure Manifold
Pre Treatment: NONE
PUMP REQUIRED
Additional Specifications: Adding 2 additional drainlines to existing bed. Pressure manifold will have 3 taps (2 for new lines, 1
to feed existing bed)
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
»»> DO NOT INSTALL SYSTEM UNDER WET CONDITIONS <<<<<
Proposed Repair
Repair System Required? Required System Class: IIIB Proposed System: 25% REDUCTION
Distribution Type:: Pressure Manifold Soil LTAR: 0.35 g.p.d./ft2
chperniit 07/29/2016 12:20
4X3 • CATAWBA COUNTY Case# AUTH-07-2016-075126
:T j Public Health Department Subdivision PHIL CLINE PROP
� Environmental Health Division PIN# 362908884622
r PO Box 389, 100-A Southwest Blvd,Newton.NC 28658 LOP! 59-62 & 94-97
1842 :w
NAME ON PERMIT: CHRISTOPHER FRYE, 2153 DOVE ST,
Site Address: 2153 DOVE ST, NEWTON NC 28658
Property Size: Square Feet: 30,056.40 Acres:0.69
Directions: East Hwy 10, turn right on dove st house on the left.
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the
applicant/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements arc met. This
Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are
altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in
compliance with the provisions of the North Carolina 'Laws and Rules for Sewage Treatment and Disposal Systems' (ISA NCAC ISA
.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to
function satisfactorily for anv given neriod of time
Steven Price 07/29/2016
AUTHORIZED STATE AGENT APPROVAL DATE
Permit Expiration Date: 07/29/2021
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
chpennit 07/29/2016 12:20
1
RBPR 06-2016-24177
2153 Dove St,Newton
• Do not cut, drive, fill, or grade over septic or repair areas.
• Septic system must be 10 ft from property lines; 50 ft from wells; 5 ft from building
foundations and appurtenances; and out of right-of-ways and easements.
• Install a new 1,000 gallon pump tank and pressure manifold with 3 sch 40 %2'taps. 2
taps will feed the new drain lines and 1 tap will feed the existing bed. If it can be proven
that proper fall can be achieved from septic tank to drainfield while maintaining a
maximum trench depth of 36 inches a pump tank may not be required.
• Install 160 linear feet of 25% reduction system with maximum trench depth of 36 inches;
proposed 2 lines total at 80 ft each on contour.
• There is a gray water discharge that is required to be cut off and must be rerouted into the
septic tank.
• Final grade of septic area must shed surface water off and away from system.
17a�r