HomeMy WebLinkAboutAUTH-03-2016-069672.TIF -3•A CATA VBA COUNTY CI Case# AUTH-03-2016-069672
/v RAMBLE WOODS
T .j� ! Public Health Department " `� � Subdivision
o „/t; Environmental Health Division
'r • PIN# 375402859629
•to,
�'!f PO Box 389, 100-A Southwest Blvd,Newton.NC 28658 =� � G • LOT# 25-28
r
0 . " orb .
NAME ON PERMIT: QUICK CLAIM HOLDINGS, LLC, 1137 E MARION ST #251, SHELBY NC 28150
Site Address: 5252 RAMBLE WOODS AV, CLAREMONT NC 28610
Property Size: Square Feet: 21,780.00 Acres:0.5
Directions: Hwy 16 N/right on Oxford School Rd/Ramblewoods Ave is on left/property on right
Authorization to Construct Permit
Authorization to Construct Wastewater System (Required for Building Permit)
See site plan and number of additional attachments ( ).
Proposed Wastewater System: 25% REDUCTION Wastewater Flow 360 g.p.d
Type: IIIG -OTHER NON-CONY TRENCH SYSTEMS
Soil LTAR: 0.3 g.p.d./ft2
Permit Category: New Septic
Type of Facility: Primary Residence - house
Basement? No Basement Plumbing?No Bedrooms: 3
Wastewater System Requirements
Tank Size: New Tank 1,000 gal Pump Tank gal Grease Trap gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 900 sq ft Total Length: 300 ft Maximum Trench Depth 36 in
Aggregate Depth in Trench Width 3 ft
Minimum Soil Cover 12 in Minimum Trench Separation 9 ft on center
Number of Drain Lines 4
Distribution: Serial
Pre Treatment: NONE
Additional Specifications: Outlet plumbing from house must correspond to required septic tank and drainfield depth. If
plumbing comes out too deep, a pump will be required. Installer is to contact EHS for system
redesign if a pump is needed.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
»»> DO NOT INSTALL SYSTEM UNDER WET CONDITIONS ««<
Proposed Repair
System Class: IVA Proposed System: 50% REDUCTION Distribution Type:: LPP
Soil LIAR: 0.3 g.p.d./ft2
PUMP REQUIRED "*" OPERATOR REQUIRED
ehpennit 03/02/2016 08:18 Page 1 of4
rF CATAWBA COUNTY Case# AUTH-03-2016-069672
Public Health Department Subdivision RAMBLE WOODS
< ' Environmental Health Division PIN# 375402859629
-a PO Box 389. 100-A Southwest Blvd,Newton.NC 28658 LOT# 25-28
18•2 :.
NAME ON PERMIT: QUICK CLAIM HOLDINGS, LLC, 1137 E MARION ST #251, SHELBY NC 28150
Site Address: 5252 RAMBLE WOODS AV, CLAREMONT NC 28610
Property Size: Square Peel:21,780.00 Acres:0.5
Directions: Hwy 16 N/right on Oxford School Rd/Ramblewoods Ave is on left/property on right
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the
applicant/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This
Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are
altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in
compliance with the provisions of the North Carolina 'Laws and Rules for Sewage Treatment and Disposal Systems' (ISA NCAC I8A
.1900). Neither Catawba County nor the Environmental Ifealth Specialist warrants that the septic tank system will continue to
function satisfactorily for any given neriod of time
Megen McBride 03/02/2016
AUTHORIZED STATE AGENT APPROVAL DATE
Permit Expiration Date: 03/02/2021
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehpermit 03/02/2016 08:18 Page 2 of 4
AG 2. g 0>)olb-23257
515) Ram4l& UJooas Av, Uarer401
t 1ft5{a11 10005411ov\ sep+ic,-k is and 30041 of a57O redur ;on ; 4-75{x. -(- Lt S.
Zvvs-kik dvotih-cell on Coh-foie,
SeOic system rvvusk be 1e4 511- -Ervin *roav1e5, loft. crom
proper} lines, sof1 .•fror, any well It{a. -F"rorn work), 1irc� aNr( oat of
r;�kk o�- ways and easemeKii-
po ntk drive, rote, etA 0(4111 0UEY 90■(., afexc.
}(base wal connect -b pu191■c \t -tt
100.3'
1i0.
xkte
r
Prtreti
3 bedroom
hoose/
E boxyo
2W\ Weer 20'
dt(eCtil besiic T bxy
a1 2 `o.
' Septic/ pert'
Area 60x35 55
50?0 ,pet- Lft c115i.
No.
Qn.mbrL Woobs IV)
1;50'
F ; :