HomeMy WebLinkAboutAUTH-07-2016-074410.TIF 6A CATAWBA COUNTY Case 14 AUTH-07-2016-074410
t Mar./� Public Health Department Subdivision BAKERSVIEW MEADOWS
, p
4 IR 01 ; 8avironmcntal Health Division PIN# 279009173350
''°t?- PO Box 389. 100-A Southwest Blvd,Newton.NC 28658 LOT# 1
1H42 ;,w
NAME ON PERMIT: PETRICA STOIAN, 1437 SWEETBRIAR LN, HICKORY NC 28602
Site Address: 5877 PINEWINDS DR, HICKORY NC 28602
Property Size: Square Feet: 22,215.60 Acres:0.51
Directions: 127 S /to Pindwinds Dr/ go right/ lot on left
Owner/Authorized Representative Acknowledgement of Permit Receipt
M certify that I am the owner or authorized agent(owner's authorization required) representing the owner of the
�A property described above.
7' �S As the property owner or authorized representative, I have received the above referenced permit(s) as
requested in the application for service RBPR-06-2016-24077 by the following method(s):
Received in Person
Facsimile Transmittal (Return form with signature required)
Electronic Image Transmittal/ E-mail (Return receipt required)
�5 As the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the North
Carolina Laws and Rules for Sewage Treatment and Disposal Systems (15A NCAC 18A .1900), and/or
Well Construction Standards (15A NCAC 2C .0100), shall apply to the issuance of this permit and the
construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 07/12/2016 ,/
_ Owner/Authorized Representative Signature
Date 7 (,? ( C l/
Documentation of Permit(s) Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name ofperson sending permit)
Signature Date/Time
Method: Fax Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We want to hear from you. Please take a few moments to complete our customer service survey at:
http://www.surveymonkey.com/s/EHCustomerService
chpennit 07/12/2016 11:18
��A •� CATA VBA COUNTY 0 • �0 '� 0 Case# AUTH-07-20 1 6-0744 1 0
,A" Public Health Department r Subdivision BAKERSVIEW MEADOWS
v Y Environmental Health Division .; .r PIN# 279009173350
'"45'Y PO Box 389, 100-A Southwest Blvd,Newton.NC 28658 ,Dr LOT# 1
I8.2 ,� : . • -
F O _all
D .4..I:1 • . .
NAME ON PERMIT: PETRICA STOIAN, 1437 SWEETBRIAR LN, HICKORY NC 28602
Site Address: 5877 PINEWINDS DR, HICKORY NC 28602
Property Size: Square Feet:22,215.60 Acres:0.51
Directions: 127 S/to Pindwinds Dr/go right/ lot on left
Authorization to Construct Permit
Authorization to Construct Wastewater System (Required for Building Permit)
* See site plan and number of additional attachments ( ).
Proposed Wastewater System: 25% REDUCTION Wastewater Flow 360 g.p.d
Type: 111G -OTHER NON-CONY TRENCH SYSTEMS
Soil LTAR: 0.275 g.p.d./ft2
Permit Category: New Septic
Type of Facility: Primary Residence -
Basement? No Basement Plumbing?No Bedrooms: 3
Wastewater System Requirements
Tank Size: New Tank 1,000 gal Pump Tank gal Grease Trap gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 990 sq ft Total Length: 330 ft Maximum Trench Depth 30 in
Aggregate Depth in Trench Width 3 ft
Minimum Soil Cover 12 in Minimum Trench Separation 9 ft on center
Number of Drain Lines 3
Distribution: Serial
Pre Treatment: NONE
Additional Specifications: Surface water diversion required along eastern property line above the septic system.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
»»> DO NOT INSTALL SYSTEM UNDER WET CONDITIONS ««<
Proposed Repair
Repair System Required? Required System Class: IVA Proposed System: 50% REDUCTION
Distribution Type:: LPP Soil LTAR: 0.275 g.p.d./ft2
PUMP REQUIRED
ehpennil 07/12/2016 11:18
,rP CATAWBA COUNTY Case N RUTH-07-2016-074410
,7" IQ Public Health Department Subdivision BAKERSVIEW MEADOWS
<v--,®1, 4 Environmental Health Division PINT{ 279009173350
•+t.Y PO Box 389, 100-A Southwest Blvd.Newton,NC 28658 LOTH 1
18.2 o
NAME ON PERMIT: PETRICA STOIAN, 1437 SWEETBRIAR LN, HICKORY NC 28602
Site Address: 5877 PINEWINDS DR, HICKORY NC 28602
Property Size: Square Feet:22,215.60 Acres:0.51
Directions: 127 S/to Pindwinds Dr/go right/ lot on left
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the
applicant/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This
Authorization to Construct Permit is subject to revocation if the site plan, plat or the intended use changes,or if site conditions are
altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in
compliance with the provisions of the North Carolina 'Laws and Rules for Sewat'e Treatment and Disposal Systems' (15A NCAC ISA
.1900). Neither Catawba County nor the Environmental Ilealth Specialist warrants that the septic tank system will continue to
function satisfactorily for any often neriod of time
Steven Price 07/12/2016
AUTHORIZED STATE AGENT APPROVAL DATE
Permit Expiration Date: 07/12/2021
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
chpenuit 07/12/2016 11:18
RBPR 06-2016-24077
5877 Pinewinds Dr, Hickory
• Do not cut, drive, fill, or grade over septic or repair areas.
• Septic system must be 10 ft from property lines; 50 ft from wells; 5 ft from building
foundations and appurtenances; and out of right-of-ways and easements.
• Install a new 1,000 gallon septic tank.
• Install 330 linear feet of 25%reduction system with maximum trench depth of 30 inches;
laid out 3 lines total (110 ft each)on contour.
• Surface water diversion is required along the eastern property line above the septic
system.
• Final grade of septic area must shed surface water off and away from system.
sus 9r
\kva*
t AA (
A.
firr_ 0 5 \ c'
r
5° 1 ti
P;ss■bl< de,l--jtA ,� i 65• tt 4
r
9e. &..a . Site nd tpo' f.)is_
2g4,(tai ckee.4.61 VtSO
GA bti:Nr, se-ga.i3