HomeMy WebLinkAboutAUTH-06-2016-073746.TIF CATAWBA COUNTY Q ' ;or Case# AUTFI-06-2016-073746•46 t
• _ Subdivision
:,::,211,-; Public Health Department �+i�.
< 140 ,tip, Environmental Health Division g ti • 7 PIN# 269902691861
\'°da PO Box 389, 100-A Southwest Blvd,Newton.NC 28658 I LOT#
/g.2 s. .: x f
0 {sue t •
NAME ON PERMIT: JESSE MALLEAUX, 3351 2ND ST PLf NW, HICKORY NC 28601
Site Address: 1176 WISTERIA DR, HICKORY NC 28602
Property Size: Square Feet: 620,294.40 Acres:14.24
Directions: Hwy 127 in Mountain View, on to Huffman Farm Rd, turn right on Pittstown Rd, First right on to River Birch,
turn 2nd Left on to Mulberry, first right onto Winding Oak Dr, first left onto Wisteria Dr. Gate at very end of
cul-de-sac
Authorization to Construct Pettnit
Authorization to Construct Wastewater System (Required for Building Permit)
* See site plan and number of additional attachments ( ).
Proposed Wastewater System: 25% REDUCTION Wastewater Flow 720 g.p.d
Type: IIIB - SYSTEM W/SINGLE EFFLUENT PUMP
Soil LTAR: 0.35 g,p.d./ft2
Permit Category: New Septic
Type of Facility: Prim Res/Acc Dwelling -
Basement? Yes Basement Plumbing? Yes Bedrooms: 6
Wastewater System Requirements
Tank Size: New Tank 1,500 gal Pump Tank 1,500 gal Grease Trap gal
Dosing Volume 235 gal Pump Specs: 35.55 GPM @ 18.52 TDH
Pressure Head 2 ft Draw Down 11.2 in
Drainfield: Total Area: 1,545 sq ft Total Length: 515 ft Maximum Trench Depth 24 in
Aggregate Depth _in Trench Width 3 ft
Minimum Soil Cover 12 _ in Minimum Trench Separation 9 ft on center
Number of Drain Lines 5
Distribution: Pressure Manifold
Pre Treatment: NONE
PUMP REQUIRED
Additional Specifications:
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
»»> DO NOT INSTALL SYSTEM UNDER WET CONDITIONS ««<
Proposed Repair
Repair System Required? Required System Class: IVA Proposed System: DRIP IRRIGATION
Distribution Type:: Drip Irrigation Soil LTAR: 0.125 g.p.d./ft2
PUMP REQUIRED ***** OPERATOR REQUIRED
chpemi it 06/21/2016 09:07 Page I of 4
Ogg";CV CATAWBACOUNTY Case# AUTH-06-20 1 6-073 746
Public Health Department Subdivision
omEnvironmental Health Division PIN# 269902691861
PO Box 389, 100-A Southwest Blvd,Newton,NC 28658 LOT#
lg42 ,u
NAME ON PERMIT: JESSE MALLEAUX, 3351 2ND ST PL NW, HICKORY NC 28601
Site Address: 1176 WISTERIA DR, HICKORY NC 28602
Property Size: Square Feet:620,294.40 Acres:14.24
Directions: Hwy 127 in Mountain View, on to Huffman Farm Rd, turn right on Pittstown Rd, First right on to River Birch,
turn 2nd Left on to Mulberry, first right onto Winding Oak Dr, first left onto Wisteria Dr. Gate at very end of
cul-de-sac
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of
the applicant/property owner to insure that all Catawba County Planning/Zoning and 13uilding Inspections requirements are met.
This Authorization to Construct Permit is subject to revocation if the site plan, plat or the intended use changes,or if site
conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit
was issued in compliance with the provisions of the North Carolina 'Laws and Rides for Sewage Treatment and Disposal Systems' (15A
NCAC 18A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will
continue_to function satisfactorily for any siven period of time
Steven Price 06/21/2016
AUTHORIZED STATE AGENT APPROVAL DATE
Permit Expiration Date: 06/21/2021
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehpermit 06/21/2016 09:07 Pagc2of4
RBPR 04-2016-23736
1176 Wisteria Dr,Hickory
AC
• Do not cut, drive, fill, or grade over septic or repair areas.
• Septic system must be 10 ft from property lines; 100 ft from wells and streams; 15 ft
from basements; 5 ft from appurtenances; and out of right-of-ways and easements.
• Install a new 1,500 gallon septic tank and 1,500 gallon pump tank,pumped to pressure
manifold with 5 sch 40 '/z"taps.
• Install 515 linear feet of 25%reduction system with maximum trench depth of 24 inches;
proposed(5) lines 103 ft each on contour.
• Final grade of septic area must shed surface water off and away from system.
• Reference tree, oak with ribbon wrapped around it must be left in place until system is
installed as a reference.
WELL
• Well should be 5 ft from property lines;25 ft from structures; 100 ft from septic systems;
and out of right-of-ways and easements.
�,►� wef.
greL
C /...
rut-9
ers
J.
:l, j1
r, I
y
•l
0,sr
r 'y'
\ Orr
A rot
eCe •
WS/7 y3 . 44.04" 0:01/-1:.:04 gYi"sw=1;j 7 t x' - .: .l .. 3IG"-I f . .rs.g . e 1.