Loading...
HomeMy WebLinkAboutOP-05-2016-072468.TIF 44$' • CATAWBA COUNTY 0 �o}�. 0 Case# OP-05-2016-072468 H .,fl . Public Health Department „tip .. Subdivision LAKEPOINTE SOUTH tt '-'3 Environmental Health Division PIN# 462801269196 PO Box 389, l00-A Southwest Blvd,Newton,NC 28658 ��o' �.��. LOT# 16 Ig, sM *`... 0 _.o. 14 . NAME ON PERMIT: KENNETH JAMISON, 2612 PENNGATE DR, SHERRILLS FORD NC 28673 Site Address: 9271 BELLE PINES CT, SHERRILLS FORD NC 28673 Property Size: Square Feet:31,363.20 Acres:0.72 Directions: 150 to Sherrills Ford Rd to Island Point Rd to Camden Points Rd turn R go to Belle Pines Catawba County Health Department Operation Permit System Type: IIIG -OTHER NON-CONV TRENCH SYSTEMS (In accordance with Table Va) Description: 25% REDUCTION System Code: IQ4W System Code Description: Infiltrator Quick 4 Standard W Types V and VI systems expire in 5 years. Owner must contact health department 6 months prior to expiration for permit renewal. System Installation Comments: Installed 315 linear feet of infiltrator at 36"depth based on a .375 LTAR to help meet multiple 100'well setbacks and allow additional room to drill new proposed well on lot. Well not drilled at time of inspection. See surveyed site plan. Adrian Pruett LSS had shot in and flagged additional drain field during proposal and proposed a .4 LTAR. System was designed at lowest range of LIAR but determined during preconstruction conference with installer that total amount of drain field could be lowered due to installation depth and saprolite conditions. Lower line marked in field not installed. Line lengths were 70',62' 58', 54'46' 25'. End of trenches were to be marked with blue flags provided by EHS to installer after system was covered up. PERMIT CONDITIONS: 1. All maintenance, monitoring, and performance requirements shall be in accordance with 15A NCAC 18.1900, Rule .1961 2. Operation & Maintenance Specifics: Subsurface system operator required? Yes No_X_ If yes, see attached sheet for additional operation conditions, maintenance and reporting. This system has been installed in compliance with applicable North Carolina General Statutes, Rules for Sewage Treatment and Disposal, and All conditions of the Improvement Permit and Construction Authorization. Britt Bass#1019 05/16/2016 SYSTEM INSTALLER INSTALLATION DATE Jason Boyd 05/17/2016 AUTHORIZED STATE AGENT DATE OF OPERATION PERMIT Form F ISSUANCE ehpermit 05/17/2016 09:32 Page 1 of3 * N w P 3 0 Cl. H 3 m (n �' a s b A a a et-a LINE TABLE _ N.p -� LINE LENGTH BEARING O Lt 9.94 S85'20'24'E i r` `C► J J r00• a nE �1O,GS BELLE PI E,s Co UR T e Cg NE T/E _ DDEE E—_2_YALLE�' CURB 50 PUBLIC R/W .6' BC TO BC C4 e C3 uLt S85'16'S0"E 159.14' Alt r-- .�_ 10" U TY & DRAT AGE EA ‘1,,, CN JI + .FE2iT SETBACK / . 4628-0125-6749 i Robert Wagner Yt' GARAGE / I Marilyn Wagner a iOB 3775 PG w/ s,` ' sod ' b N. BASEMENT 5 9' / . J � � c � 1 r I :12 LOT 16 `b. LT SQ.FT_ � I IaI . 14 / 7 1. 721 ACRES N ,%'1 O I C S. I S. n S-�T�1?Y DRALNA I 5. J N8229'16"W � N_ / 194.57' b / / 4828-0126-9060 Tony G Gowan OB 3133 PG 223 t TY At DRAINAGE WAGE EASEMENT 20 Ir �,. 1 II i 0 IL rn '"1 �. 01 N m • 1 i WN (j W Z .',1(0 O CO m (C go. C 1 -t- ,:o ', r. t e, D k to J ) .3 LEGEND L C 05 REBAR FOUND 0 1-- /4 REBAR SET QL COMPUTED POINT • L t' (' BORE HOLE OD t° LOCATION N aN 1 P 1 3