HomeMy WebLinkAboutAUTH-05-2016-072462.TIF • CATAWBA COUNTY a : - Q Case# AUTH-05-20 1 6-072462
.T Eti 1 Public Health Department 'f �s ' .JAI' Subdivision RIVER RUN
c6eJa i '.
®,• �''� Environmental Health Division t •.r �� : PIN# 360902757894
� PO Box 389. 100-A Southwest Blvd,Newton.NC 28658 � '� LOT# 30-31
Ig42 ,,, —
NAME ON PERMIT: BRAD HUDSON, 4608 DIAMOND ST, CLAREMONT NC 28610
Site Address: 4310 RIVER RUN CIR, HICKORY NC 28602
Property Size: Square Feet:344,995.20 Acres:7.92
Directions: Hwy 10 W, right Finger Bridge Rd, r into River Run Subdivision, middle of River Run Circle
Authorization to Construct Permit
Authorization to Construct Wastewater System (Required for Building Permit)
* See site plan and number of additional attachments ( ).
Proposed Wastewater System: 25% REDUCTION Wastewater Flow 480 g.p.d
Type: IIIG -OTHER NON-CONY TRENCH SYSTEMS
Soil LTAR: 0.3 g.p.d./ft2
Permit Category: New Septic
Type of Facility: Primary Residence -
Basement? Yes Basement Plumbing? Yes Bedrooms: 4
Wastewater System Requirements
Tank Size: New Tank 1,000 gal Pump Tank gal Grease Trap gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: _
1,200 sq ft Total Length: 400 ft Maximum Trench Depth 24 in
Aggregate Depth in Trench Width 3 ft
Minimum Soil Cover 12 in Minimum Trench Separation 9 ft on center
Number of Drain Lines 5
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
»»> DO NOT INSTALL SYSTEM UNDER WET CONDITIONS ««<
Proposed Repair
System Class: IIIF Proposed System: 10" LARGE DIAMETER PIPE Distribution Type:: Serial
Repair System Required? Required Soil LIAR: 0.3 g.p.d./ft2
chpenuit 05/1712016 09:06 Page 1 or4
cwA CATAWBA COUNTY Case f AUTH-05-2016-072462
ri �G Public Health Department Subdivision RIVER RUN
< H Environmental Health Division PINII 360902757894
1114 040
- PO Box 389, 100-A Southwest Blvd, Newton, NC 28658 LOT# 30-31
/8.1 ,M
NAME ON PERMIT: BRAD HUDSON, 4608 DIAMOND ST, CLAREMONT NC 28610
Site Address: 4310 RIVER RUN CIR, HICKORY NC 28602
Property Size: Square Feet: 344,995.20 Acres:7.92
Directions: Hwy 10 W, right Finger Bridge Rd, r into River Run Subdivision, middle of River Run Circle
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the
applicant/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This
Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are
altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in
compliance with the provisions of the North Carolina 'Laws and Rules for Sewatse Treatment and Disposal Systems' (15A NCAC 18A
.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to
function satisfactorily for any riven neriod of time.
Steven Price 05/16/2016
AUTHORIZED STATE AGENT APPROVAL DATE
Permit Expiration Date: 05/14/2021
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehperm it 05/17/2016 09:06 Page 2 of4
RBPR 04-2016-23566
4310 RIVER RUN CIRCLE,HICKORY
• Do not cut, drive, fill, or grade over septic or repair areas.
• Septic system must be 10 ft from property lines; 50 ft from any wells and streams; l0 ft
from water lines; 15 ft from a basement; and out of right-of-ways;and easements.
• Install a 1,000 gallon septic tank and 400 linear feet of 25%reduction system; (5) 80 ft
lines on contour.
• Final grade of septic area must shed surface water off and away from system.
266
o
aA
Io"
^I J/ /IJ�'I
A\:
l0 10�1,0 e
\ p
\ o' —
— Ilk
v"V A ?2'Jcs3'
\ 186
I i• n
1 �C;v Cr Rw C,', ° co