Loading...
HomeMy WebLinkAboutAUTH-10-09-1601.TIF CONSTRUCTION For OfficeUse Only, AUTHORIZATION *CDP File ~Nu"mber' 3 5 7 3. 6 Catawba County Public Health Department County ID N,umber: ~Hp 11) bq P/9q Environmental Health Division Evaluated For. REPAIR 01 P.O Box 389, 100-A Southwest Blvd PERMIT VALID UNTIL: a✓~D Newton NC 28658 1 0/ a 6/ a 0 1 4 Phone: (828)-465-8270 Fax: (828) 465-8276 Applicant: Randy Rutkai Property Owner: Randy Rutkai Address: 137 Cross Center Dr. Address: 137 Cross Center Dr. City: Denver 7 City: Denver State/Zip: NC 28037 State/Zip: NC 28037 Phone Phone Property Location & Site Information Address/Road Subdivision: Stonecroft Phase: Lot: 54 6226 Neptune Rd. Denver NC 28037 Directions Structure: SINGLE FAMILY # of Bedrooms: 3 # of People: 6 *Water Supply: PUBLIC System eci Ica ions Minimum Trench Depth: T es *Site Classification: PS Minimum Soil Cover: 0 6 Inches Design Flow: 3 6 0 Maximum Trench Depth: 3 0 Inches Soil Application Rate: 0 3 Maximum Soil Cover: Inches 'System Classification/Description: *Distribution Type: PRESSURE MANIFOLD TYPE III B. SYSTEM W/SINGLE EFFLUENT PUMP Septic Tank: Gallons *Proposed System: 50% REDUCTION 1-Piece: QYes QNo Nitrification Field 6 0 0 Pump Required: QYes QNo Q May Be Required Sq. ft. No. Drain Lines Pump Tank: 1 0 0 0 Gallons 4 1-Piece: QYes QNo Total Trench Length: a 0 0 ft. GPM--vs-- ft. TDH Trench Spacing: 8 Qlnches O.C. - Feet O.C. Dosing Volume: Gallons Trench Width: a Qlnches - -0Feet Aggregate Depth: Grease Trap: Gallons inches Pre-Treatment: Q NSF QTS-1 QTS-11 Septic Tank Installer Grade Level Required: 01 NII 0111 01V Page 1 of 3 CDF File Number 35736 County ID Number: ❑ Open Pump System Sheet Repair System Required:OYes O No ONo, but has Available Space Repair System Trench Spacing: Olnches O.C. *Site Classification: - O Feet O.C. Trench Width: 0Inches Design Flow: _ Feet Soil Application Rate: Aggregate Depth: inches u Minimum Trench Depth: 'System Classification/Description: Inches Minimum Soil Cover: Inches Maximum Trench Depth: 'Proposed System: Inches Maximum Soil Cover: Nitrification Field Inches Sq. ft. No. Drain Lines 'Distribution Type: Total Trench Length: ~ Pump Required: OYes ONo OMay Be Required Pre-Treatment: O NSF OTS-I OTS-II Site Modifications No grading or construction activity is allowed in areas designated for system and repair without approval of Health Department. *Permit Conditions The issuance of this permit by the Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. Septic system must be at least 100 ft. from any well, 10 ft. from property lines, 5 ft. from structures, Install on contour. Do not drive, grade, cut, or fill over septic area. Install as much linear feet as will fit and still maintain the required setbacks. Septic installer must call several days prior to installation to schedule a site visit. At this time, purnp requirements will be calculated and the system will be laid out. This Authorization for Wastewater System Construction shall be valid for a person equal to the period of validity of the Improvement Permit, not to exceed five years, and may be issued at the same time the Improvement Permit issued (NCGS 130A-336(b)). If the installation has not been completed during the period of validity of the Construction Permit, the information submitted in the application for a permit or Construction Authorization is found to have been incorrect, falsified or changed, or the site is altered, the permit or Construction Authorization shall become invalid, and may be suspended or revoked (.1937(g)). The person owning or controlling the system shall be responsible for assuring compliance with the laws, rules, and permit conditions regarding system location, installation, operation, maintenance, monitoring, reporting and repair (1938(b)). Applicant/Legal Reps. Signature Required? OYes ONO Applicant/Legal Reps. Signature Date: I It I /0-7 'Issued By: 2246-Megen McBride Date of Issue: 1 0/ a 6/ a 0 0 9 Authorized State Agent: Malfunction Log OYes C~ Hand Drawing OI mport Drawing Total Time:(HH:MM) **Site Plan/Drawing attached.** 0 Hours Minutes Page 2 of 3 CDP File Number. 35736 County ID Number: Drawing Type: Construction Authorization Date: 1 0 a 6/ a 0 0 9 OInch Scale: QBIock = ft. Drawini NIA C~~4a.(1-~{---5 ~vcr~(nes_o n45 -vv 4 N^; dal I { See v~eV\0~5, e _~Y r}Io~a( ve ulre ek~}s 'S• n Se{-1~. QC, I(D~ t S}M i- i I I PYQSSvre. I Oic l S ~ ly 21 C,rP e t ~ a new P~P-}~ i i : i , i r i Page 3 of 3 INUUtZINK Division of, Environmental Health 'Date: 10 l a 0 1 2009 On-Site Wastewater Section Soil/Site Evaluation 'File: 3 s 7 3 6 For On-Site Wastewater System PIN: 'Owner Randy Rutkai Proposed Facility SINGLE FAMILY Proposed Design Flow(. 1949) 3 6 0 Location of Site 6226 Neptune Rd. Property Size • q7 (L(Ke Water Supply PUBLIC Evaluation Method Auger 1940 Horizon SOIL MORPHOLOGY Profile # Landscape Depth .1941 Other Profile POS Slope % (IN) Mineralogy Matrix Mottle Factors Texture Structure Consistence Color Color 1 L 0-30 CL 2-Mode sbk fr ss sp .1942 Wet. % 30-42 C 2-Mod+ sbk fr ss sp .1943 Depth 4 a ps GPS Saprolite: (in) .1944 Rest. Horizon Fny' EHS .1947 Class ps Megen MCBri, Profile 0 3 LTAR .1942 Wet. % .1943 Depth GPS Saprolite (in) .1944 Rest. Horizon ' .1947 Class = EHS Cop. rofile Profile LTAR - 1942 Wet. % .1943 Depth GPS Saprolite:(in) 144 Rest. onzon E H S 1947 Class Cop rofile Profile LTAR u .1942 !Net. % .1943 Depth GPS Saprolite_(in) .1944 Rest_ Horizon EH5 _1947 Class Copy rofile Profile u LTAR .1942 Wet- % .1943 Depth GPS Saprolite:(in) .1944 Rest. Horizon ° EH5 1947 Class Cop, rofile Profile LTAR - Available Space (.1945) PS Other Factors(.1946) PS Site Classification (.1948) Ps Initial LTAR: Repair LTAR: 0 . 3 Others Present: Boyd, Jason Commen tS: Available space is very limited. Evaluated By: Megen McBride 114 k. UIZZIVr\ Division,of Environmental Health On-Site Wastewater Section Date: Soil/Site Evaluation File 3 s 7 3 6 For On-Site Wastewater System PIN: 1940 Horizon SOIL MORPHOLOGY Profile# Landscape Depth .1941 Other Profile POS Slope % (IN) Mineralogy Matrix Mottle Factors Texture Structure Consistence Color Color .1942 Wet- % .1943 Depth GPS Saprolite:(in) .1944 Rest. Horizon .1947 Class ` EHS CopyrProfile Profile LJ LTAR .1942 Wet. % .1943 Depth GPS Saprolite:(in) .1944 Rest. Horizon EHS .1947 Class CopyElrofile Profile LTAR - .1942 Wet- % .1943 Depth GPS Saprolite:(in) 1944 Rest. Horizon r^ EHS 1947 Class Copy Profile Profile u LTAR " .1942 Wet. % 1943 Depth GPS Saprolite:(in) 19.44,Rest r orrzon EHS 1947 Class Copv[Profile P~oAf e u .-1942 Wet. % .1943 Depth GPS Saprolite:(in) 1W Rest. orizon f''• EHS .1947 Class ` Copyofile Profile 19r LTAR Comments: Fn «aL.II iinayc The "Open Drawing Form" button, opens the the drawing form. The "Import" button, attaches the drawing, or other image into the space below. Open Drawing Form 7:5 0 u0 i\6 n r ~~~~r C ~ro~ SC~e - ~W ~v ~Glir ~OC~4t~ h Profile: 1 X Y Z Profile: 1 X . Y Z Profile: X Y Z Profile: ^l X Y Z Profile: X Y Z Profile: X . Y Z Profile: Cj X • Y Z Profile: 4.i X Y Z Profile: X Y Z Profile: X Y • Z EHPR-10-09-2144 Rutkai TRACKING INFORMATION Date Calls 10/20/2009 1st Contact- Discussion Only ...(mm) Made site visit to do soil evaluation. No one was at home. 10/20/2009 Site Ready to be Flagged... for tracking purposes only. 10/20/2009 Site Flagged ...for tracking purposes only 10/20/2009 Site Ready to be Evaluated ...(mm) 10/20/2009 Site Evaluated ...(mm) Daily rain slightly delayed my site visit/soil evaluation. Existing septic system is still failing. 10/20/2009 Approved for Issuance... (mm) Other See also CMP2009-00082 Date Comments/Field Notes 10/21/2009 10/21/2009 (MM) Called Mr. Rutkai. Did not reach him...left a message. Said that I'd been to his lot and done the necessary evaluation and I would call him once the permit was ready for him to pick up. 10/22/2009 (MM) Mr. Rutkai left me a message. He was just wondering if he needed to meet me on site. 10/23/2009 (MM) Returned Mr. Rutkai's call. Did not reach him. Did not leave a message. 10/26/2009 (MM) Issued Mr. Rutkai's repair permit. 10/27/2009 (MM) Called Mr. Rutkai. Did not reach him. Left him a message that stated his permit was ready for him to pick up. Said that he would have to come to our office and sign for it. Also told him that if he had any questions concerning the permit that he could call me. Also mentioned that he is currently in violation and needs to get this system installed quickly to avoid being referred to the county's legal dept. �-1 PP�- 9����� �� yy � �2� N����� �� . ���� a M E40/M E40AG S E R I ES Submersible Sump, Effluent & Sewage Pumps Installation and Service Manual Automatic and manual models. Single phase power only —115 or 230 volt. �, � ,� {€�� � , e . , � � � ,,.. q 4 r � :��� � � -���� � � � .,.,, � �'� � ` k "� § �� �:� - � h �,�_� &, � -; � �. � .. Y' s,w. " �• a � i, � r ��" . � �,�'' � .; � , ��` � � I i � � . 4.""� i �'�;, . i j ��� �) _ ���� . i� i l+ �II� �' ��UIM�� � . � .. , I� � I ( � a � �� � �' " /, `� ",< ; �'; ( �- .. ...,._ R3 t� �. ` T.v: — ' �Il i ' r �� I') �� I �� ' � ff � . _ i � � Pentair� 23833A245 (Rev. 8/6/09) DESCRIPTION AND APPLICATION PACKAGING ME40 Each pump is packaged separately in a carton marked Myers ME40 Series Pumps are single seal units, with a catalog number and Myers engineering number. automatic or manual, designed for use in effluent dosing. Septic Tank Effluent Pumping (S.T.E.P.) or Catalog Engineering Cord normal sump and general dewatering applications No. No. HP V Ph L th. T e where higher pressure is required. DO NOT USE FOR ME40A-11 25300D000 4/10 115 1 10' Auto ME40M-11 25300D001 4/10 115 1 10' Manual RAW SEWAGE. ME40AC-11 25300D010 4/10 115 1 20' Auto ME40MC-11 25300D011 4/10 115 1 20' Manual When used in effluent dosing or S.T.E.P. applications ME40AC-21 25300D012 4/10 230 1 20' Auto the pump must be installed in a separate tank or ME40MC-21 25300D013 4/10 230 1 20' Manual compartment at the discharge side of the septic tank. ME4oP-1 25300D900 4/10 115 1 10' Auto NEVER INSTALL PUMP IN MAIN TANK WHERE ME40PC-1 25300D901 4/�0 115 1 20' ,4uto SLUDGE COLLECTS. MEaoP-2 25300D902 4/10 230 1 10' Auto ME40PC-2 25300D903 4/10 230 1 20' Auto �mpellers are enclosed two-vane type to handle ME40AG-11 27234D001 4/10 115 1 20' Manual 3/4" spherical solids and are made of engineered ME40AG-21 27234D002 4/10 230 1 20' Manual thermoplastic. All pumps have a 1-1/2" NPT LEVEL CONTROLS discharge tapping. NOTE: DO NOT OVERTIGHTEN All pumps must use sealed level control switches for DISCHARGE PIPE INTO PUMP PLASTIC automatic operation. All automatic pumps have built- DISCHARGE FITTING. in level control float switches. The power cord has a GROUND PIN that plugs into a grounded receptacle. General The grounded receptacle cannot be used in the wet These pumps are available in 115 volt or 230 volt, sump or basin due to DANGER of current leakage. single phase, 4/10 HP motors. All units are single seal only, available in automatic or manual with either 10' or Manual pumps can be made automatic with MLC or 20' power cords. All power cords have either 115 volt MFLC controls with a series plug. Plug the MLC or or 230 volt grounded plugs. MFLC witch cord series plug into a proper voltage GROUNDED RECEPTACLE. Then plug the pump These pumps are NOT for use in swimming pools or cord plug into the back of the switch cord series plug. fountains. NOTE: The float control must be tethered a minimum 4" to pump or discharge pipe. Control must float free ME40AG from pump and basin wall. The ME40AG Series Pumps are single seal units On all duplex units or simplex installations with designed for use in continuous run agricultural additional options like high water alarm, the power evaporative cooling applications. They will run cord plug must be cut off and wired into a control continuously in elevated temperatures with clean panel or into a sealed junction box if used in wet sump sump water. or basin. The AWS-1 control aiso acts as a sealed junction box for connecting power cord to pump cord. The wetted pump components are the same as already described for the ME40 series. NOTE: The ME40 sump/effluent pump can be easily changed from one style, automatic or manual, to the A1R LOCKING other by only interchanging the plug ends of the float control with the manual plug. The ball float must be A sump pump is said to be air locked if water traps air tethered with a cable clamp, as in the pump and it cannot get out, thus preventing the shown. DO NOT REMOVE THE pump from operating. MOTOR CAP. _ The ME40/ME40AG pumps have a 1/16" air vent hole The ME40P pumps have a mechanical (mercury free) float in the impeller chamber to let out trapped air. If this switch with a 10' or 20' cord with a � hole becomes plugged, the pump may air lock. As � a secondary precaution a 1/8" hole should be drilled 115 volt or 230 voit piggyback in the dischar e i e below the check valve. The plug with the switch mounted to � 9 P P the pump. Plug the switch cord check valve should be 12 to 18 inches above pump plug into a proper voltage, properly discharge. Do not put check valve directly into pump grounded outlet and plug the discharge opening. power cord into the back of the switch cord and tape the cords to the discharge pipe every 12". 23833A245 2